protogrid

Search / software.brainiac/solar-design

BRAINIAC Solar PV Design Calculations

R0· no sign-in

Paid Solar PV Design Calculations API via x402. Unpaid tool calls return 402.

v1.0.1 · active · website · descriptor JSON · versions

An agent can connect right now, no human step.Remote endpoint, no authentication, reachable on the last probe.
Quality80good
Trust83of 100
Uptime, 30 days100%
Latency p50135 msp95 416 ms

Connect

8 clients · secrets stay placeholders
Add to CursorAdd to VS Codeopens the client, which asks before adding the server
{
  "mcpServers": {
    "solar-design": {
      "type": "http",
      "url": "https://www.brainiac.software/mcp/solar-design"
    }
  }
}
claude mcp add --transport http solar-design https://www.brainiac.software/mcp/solar-design
[mcp_servers.solar-design]
url = "https://www.brainiac.software/mcp/solar-design"
{
  "$schema": "https://opencode.ai/config.json",
  "mcp": {
    "solar-design": {
      "type": "remote",
      "url": "https://www.brainiac.software/mcp/solar-design",
      "enabled": true
    }
  }
}
{
  "mcpServers": {
    "solar-design": {
      "type": "http",
      "url": "https://www.brainiac.software/mcp/solar-design"
    }
  },
  "deeplink": "cursor://anysphere.cursor-deeplink/mcp/install?name=solar-design&config=eyJ0eXBlIjoiaHR0cCIsInVybCI6Imh0dHBzOi8vd3d3LmJyYWluaWFjLnNvZnR3YXJlL21jcC9zb2xhci1kZXNpZ24ifQ%3D%3D"
}
{
  "servers": {
    "solar-design": {
      "type": "http",
      "url": "https://www.brainiac.software/mcp/solar-design"
    }
  },
  "deeplink": "vscode:mcp/install?%7B%22name%22%3A%22solar-design%22%2C%22type%22%3A%22http%22%2C%22url%22%3A%22https%3A%2F%2Fwww.brainiac.software%2Fmcp%2Fsolar-design%22%7D"
}
{
  "mcpServers": {
    "solar-design": {
      "httpUrl": "https://www.brainiac.software/mcp/solar-design"
    }
  }
}
extensions:
  "solar-design":
    enabled: true
    name: "solar-design"
    type: streamable_http
    uri: "https://www.brainiac.software/mcp/solar-design"
    timeout: 300

Quality 80 / 100good

protocol75 · weight 25
  • warn
    protocol.modernnewest supported version is 2025-11-25; 2026-07-28 not supported, older versions are deprecated until 2027-07-28
  • n/a
    protocol.statelessonly applies to 2026-07-28 servers
  • pass
    protocol.transportstreamable HTTP
  • n/a
    protocol.list_ttlonly applies to 2026-07-28 servers
authorizationn/a · weight 15
  • n/a
    auth.prm, auth.as_metadata, auth.cimdno remote uses OAuth
  • n/a
    auth.secret_in_urlno templated URL
tool hygiene100 · weight 30
  • pass
    tools.descriptionsevery tool has a description
  • pass
    tools.description_lengthdescriptions are concise
  • pass
    tools.schemasevery tool has an object input schema
  • pass
    tools.annotations15 of 15 tools declare readOnlyHint or destructiveHint
  • pass
    tools.directory_hintsevery tool declares readOnlyHint, destructiveHint, idempotentHint and openWorldHint
  • pass
    tools.token_costabout 7,295 tokens to load every tool
  • pass
    tools.api_dumptools are not a one-to-one API dump
  • pass
    tools.hidden_textno hidden text in tool names, descriptions, schemas or annotations
  • pass
    tools.poisoningno instructions aimed at the model in tool definitions
stability50 · weight 15
  • warn
    stability.changes57 tool changes in 30 days
  • fail
    stability.rug_pull16 tools kept their name but changed most of their description in 30 days; review before trusting them
  • pass
    stability.new_linksno tool change named a new site
dependenciesn/a · weight 15
  • n/a
    deps.known_vulns, deps.mcp_sdk_version, deps.resolvableno npm or PyPI package

15 tools, about 7,295 tokens to load them all · tool set fe1186e42fe6 · tools last changed 2026-11-25 · checked 2026-11-29 14:15 UTC

Definition changes

  • contact_usaddedno new version

    How to contact BRAINIAC.software support: email, page URL, what to include in a message, and what not to send. Free. Does not send email.

  • solar-design_pan-ond-parsechangeddescriptionmeaning changed
    before

    Parse PVsyst PAN (module) and OND (inverter) text files into nested raw JSON and a normalised datasheet object before you finalise a solar PV design. Call with fileType and content. Returns raw and normalized (raw includes PVObject_). Carrying a payment-signature is not yet a charge. Settlement happens only on HTTP 2xx. Invalid JSON or schema returns HTTP 400 and is not charged. HTTP 200 with status complete, partial, or failed is charged at the full listed price. HTTP 4xx/5xx are not charged. Keywords: before you finalise a solar PV design, fileType, content, raw, normalized, Parse PVsyst PAN or OND text files, pan ond parse, Solar PV Design Calculations.

    after · 41% of words in common

    Parse PVsyst PAN (module) and OND (inverter) text files into nested raw JSON and a normalised datasheet object. Docs: https://www.brainiac.software/api/solar-design/pan-ond-parse Keywords: before you finalise a solar PV design, fileType, content, raw, normalized, Parse PVsyst PAN or OND text files, pan ond parse, Solar PV Design Calculations.

  • solar-design_module-spec-comparechangeddescriptionmeaning changed
    before

    Normalise and compare module datasheet values for efficiency, W/m², temperature-adjusted power, price per watt and warranty retention before you finalise a solar PV design. Call with modules; optional referenceCellTemp. Returns modules and ranking (modules includes name, efficiency, wattsPerM2, pricePerW, pmaxAtRefTemp, warrantyYear25Retention, noct, pmaxNoct). HTTP 200 with status complete, partial, or failed is charged at the full listed price. HTTP 4xx/5xx are not charged. Keywords: before you finalise a solar PV design, modules, referenceCellTemp, ranking, Compare module datasheet metrics, module spec compare, Solar PV Design Calculations, solar design.

    after · 48% of words in common

    Normalise and compare module datasheet values for efficiency, W/m², temperature-adjusted power, price per watt and warranty retention. Docs: https://www.brainiac.software/api/solar-design/module-spec-compare Keywords: before you finalise a solar PV design, modules, referenceCellTemp, ranking, Compare module datasheet metrics, module spec compare, Solar PV Design Calculations, solar design.

  • solar-design_nec-690-currentchangeddescription
    before

    Compute PV circuit maximum current and minimum conductor ampacity using NEC 690.8 125% factors for the selected code edition before you finalise a solar PV design. Call with moduleIsc; optional edition, parallelStrings, continuousFactor. Returns maxCircuitCurrent, minConductorAmpacity, minOcpdRating, perStringMaxCurrent, and edition. HTTP 200 with status complete, partial, or failed is charged at the full listed price. HTTP 4xx/5xx are not charged. Keywords: before you finalise a solar PV design, moduleIsc, edition, parallelStrings, continuousFactor, maxCircuitCurrent, minConductorAmpacity, minOcpdRating, perStringMaxCurrent, Compute NEC 690.8 PV circuit current, nec 690 current.

    after · 56% of words in common

    Compute PV circuit maximum current and minimum conductor ampacity using NEC 690.8 125% factors for the selected code edition. Docs: https://www.brainiac.software/api/solar-design/nec-690-current Keywords: before you finalise a solar PV design, moduleIsc, edition, parallelStrings, continuousFactor, maxCircuitCurrent, minConductorAmpacity, minOcpdRating, perStringMaxCurrent, Compute NEC 690.8 PV circuit current, nec 690 current.

  • solar-design_module-layout-fitchangeddescription
    before

    Maximise the number of modules on a roof-face polygon with caller setbacks, orientation, gaps and obstruction polygons before you finalise a solar PV design. Call with roof, setback, and module; optional gap, orientations, obstructions, gridOffsets. Returns best, candidates, and placements (best includes orientation, count, rows, columns). HTTP 200 with status complete, partial, or failed is charged at the full listed price. HTTP 4xx/5xx are not charged. Keywords: before you finalise a solar PV design, roof, setback, module, gap, orientations, obstructions, gridOffsets, best, candidates, placements, Fit modules onto a roof polygon, module layout fit.

    after · 55% of words in common

    Maximise the number of modules on a roof-face polygon with caller setbacks, orientation, gaps and obstruction polygons. Docs: https://www.brainiac.software/api/solar-design/module-layout-fit Keywords: before you finalise a solar PV design, roof, setback, module, gap, orientations, obstructions, gridOffsets, best, candidates, placements, Fit modules onto a roof polygon, module layout fit.

  • solar-design_financial-paybackchangeddescription
    before

    Compute simple payback, NPV, IRR and LCOE from capex, incentives, year-1 energy, degradation, O&M and price escalation before you finalise a solar PV design. Call with capex, year1EnergyKwh, energyValuePerKwh, years, and discountRate; optional upfrontIncentives, degradation, energyEscalation, omPerYear, omEscalation. HTTP 200 with status complete, partial, or failed is charged at the full listed price. HTTP 4xx/5xx are not charged. Keywords: before you finalise a solar PV design, capex, year1EnergyKwh, energyValuePerKwh, years, discountRate, upfrontIncentives, degradation, energyEscalation, omPerYear, omEscalation, netCapex, year1CashFlow, npv, irr.

    after · 57% of words in common

    Compute simple payback, NPV, IRR and LCOE from capex, incentives, year-1 energy, degradation, O&M and price escalation. Docs: https://www.brainiac.software/api/solar-design/financial-payback Keywords: before you finalise a solar PV design, capex, year1EnergyKwh, energyValuePerKwh, years, discountRate, upfrontIncentives, degradation, energyEscalation, omPerYear, omEscalation, netCapex, year1CashFlow, npv, irr.

  • solar-design_tariff-savingschangeddescription
    before

    Compute bill savings from caller interval generation and load under a time-of-use tariff with export credit, net metering or no export value before you finalise a solar PV design. Call with loadKwh, generationKwh, and importPrice; optional intervalHours, exportMode, exportPrice, fixedCharges, demandCharge, billingPeriods. HTTP 200 with status complete, partial, or failed is charged at the full listed price. HTTP 4xx/5xx are not charged. Keywords: before you finalise a solar PV design, loadKwh, generationKwh, importPrice, intervalHours, exportMode, exportPrice, fixedCharges, demandCharge, billingPeriods, billWithoutPv, billWithPv, savings, importKwh, exportKwh.

    after · 63% of words in common

    Compute bill savings from caller interval generation and load under a time-of-use tariff with export credit, net metering or no export value. Docs: https://www.brainiac.software/api/solar-design/tariff-savings Keywords: before you finalise a solar PV design, loadKwh, generationKwh, importPrice, intervalHours, exportMode, exportPrice, fixedCharges, demandCharge, billingPeriods, billWithoutPv, billWithPv, savings, importKwh, exportKwh.

  • solar-design_battery-backup-sizingchangeddescription
    before

    Size battery energy and inverter continuous/surge power needed to back up critical loads for a target autonomy with DoD and efficiency derates before you finalise a solar PV design. Call with loads, autonomyHours, depthOfDischarge, and dischargeEfficiency; optional temperatureDerate, inverterMargin, pvRechargeKwhPerDay, simultaneousStart. HTTP 200 with status complete, partial, or failed is charged at the full listed price. HTTP 4xx/5xx are not charged. Keywords: before you finalise a solar PV design, loads, autonomyHours, depthOfDischarge, dischargeEfficiency, temperatureDerate, inverterMargin, pvRechargeKwhPerDay, simultaneousStart, energyNeededKwh, nominalCapacityKwh, inverterContinuousKw, inverterSurgeKw, Size battery backup energy and inverter power, battery backup sizing.

    after · 62% of words in common

    Size battery energy and inverter continuous/surge power needed to back up critical loads for a target autonomy with DoD and efficiency derates. Docs: https://www.brainiac.software/api/solar-design/battery-backup-sizing Keywords: before you finalise a solar PV design, loads, autonomyHours, depthOfDischarge, dischargeEfficiency, temperatureDerate, inverterMargin, pvRechargeKwhPerDay, simultaneousStart, energyNeededKwh, nominalCapacityKwh, inverterContinuousKw, inverterSurgeKw, Size battery backup energy and inverter power, battery backup sizing.

  • solar-design_system-loss-stackchangeddescription
    before

    Combine individual loss percentages into a total system loss using PVWatts multiplicative derating, with optional defaults for missing categories before you finalise a solar PV design. Call with optional losses, useDefaultsForMissing. Returns totalPercent, derate, and items (items includes name, percent, source). HTTP 200 with status complete, partial, or failed is charged at the full listed price. HTTP 4xx/5xx are not charged. Keywords: before you finalise a solar PV design, losses, useDefaultsForMissing, totalPercent, derate, items, Combine PVWatts system loss percentages, system loss stack.

    after · 50% of words in common

    Combine individual loss percentages into a total system loss using PVWatts multiplicative derating, with optional defaults for missing categories. Docs: https://www.brainiac.software/api/solar-design/system-loss-stack Keywords: before you finalise a solar PV design, losses, useDefaultsForMissing, totalPercent, derate, items, Combine PVWatts system loss percentages, system loss stack.

  • solar-design_horizon-shading-losschangeddescription
    before

    Estimate beam and isotropic sky-diffuse losses caused by a caller far-field horizon profile against sun positions and beam POA before you finalise a solar PV design. Call with horizon; optional records, latitude, longitude, elevation, times, beamPoa. Returns beamLossFraction, skyDiffuseLossFraction, and blockedHours. HTTP 200 with status complete, partial, or failed is charged at the full listed price. HTTP 4xx/5xx are not charged. Keywords: before you finalise a solar PV design, horizon, records, latitude, longitude, elevation, times, beamPoa, beamLossFraction, skyDiffuseLossFraction, blockedHours, Estimate far-field horizon shading losses, horizon shading loss.

    after · 57% of words in common

    Estimate beam and isotropic sky-diffuse losses caused by a caller far-field horizon profile against sun positions and beam POA. Docs: https://www.brainiac.software/api/solar-design/horizon-shading-loss Keywords: before you finalise a solar PV design, horizon, records, latitude, longitude, elevation, times, beamPoa, beamLossFraction, skyDiffuseLossFraction, blockedHours, Estimate far-field horizon shading losses, horizon shading loss.

Showing the latest 10. Full history: list_changes · trend: quality JSON.

Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed. How it is computed.

Trust 83 / 100

no-repository
provenance55
liveness100
freshness100
hygiene80

+dns-namespace +website +reachable +uptime-100% +updated-10d-ago -no-repository

Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed. How it is computed.

Endpoints

Last 30 days100% of probes answered
remoteauthreachableuptime 30dp50p95protocollast ok
https://www.brainiac.software/mcp/solar-design streamable-httpnoneyes100%135 ms416 ms2025-11-252026-11-29

Tools (15)

contact_usread-onlyHow to contact BRAINIAC.software support: email, page URL, what to include in a message, and what not to send. Free. Does not send email.
solar-design_battery-backup-sizingread-onlySize battery energy and inverter continuous/surge power needed to back up critical loads for a target autonomy with DoD and efficiency derates. Docs: https://www.brainiac.software/api/solar-design/battery-backup-sizing Keywords: before you finalise a solar PV design, loads, autonomyHours, depthOfDischarge, dischargeEfficiency, temperatureDerate, inverterMargin, pvRechargeKwhPerDay, simultaneousStart, energyNeededKwh, nominalCapacityKwh, inverterContinuousKw, inverterSurgeKw, Size battery backup energy and inverter power, battery backup sizing.
solar-design_dc-ac-ratio-checkread-onlyCompute the DC/AC ratio and optionally estimate AC energy and clipping from a caller DC power series with constant efficiency or a PVWatts inverter curve. Docs: https://www.brainiac.software/api/solar-design/dc-ac-ratio-check Keywords: before you finalise a solar PV design, dcNameplateKw, acRatingKw, inverterEfficiency, dcPowerSeriesKw, intervalHours, ratioWarnAbove, useCecCurve, dcAcRatio, warnings, acEnergyKwh, clippedEnergyKwh, clippingFraction, Check DC/AC ratio and inverter clipping, dc ac ratio check.
solar-design_energy-yield-estimateread-onlyEstimate AC energy from caller POA irradiance and temperatures using the PVWatts v5 DC and inverter models with a transparent loss stack. Docs: https://www.brainiac.software/api/solar-design/energy-yield-estimate Keywords: before you finalise a solar PV design, dcNameplateW, gammaPdc, acRatingW, inverterNominalEfficiency, lossesPercent, temperatureModel, records, monthly, intervalHours, totalAcKwh, lossStack, accuracyNote, Estimate AC energy with PVWatts v5, energy yield estimate.
solar-design_financial-paybackread-onlyCompute simple payback, NPV, IRR and LCOE from capex, incentives, year-1 energy, degradation, O&M and price escalation. Docs: https://www.brainiac.software/api/solar-design/financial-payback Keywords: before you finalise a solar PV design, capex, year1EnergyKwh, energyValuePerKwh, years, discountRate, upfrontIncentives, degradation, energyEscalation, omPerYear, omEscalation, netCapex, year1CashFlow, npv, irr.
solar-design_horizon-shading-lossread-onlyEstimate beam and isotropic sky-diffuse losses caused by a caller far-field horizon profile against sun positions and beam POA. Docs: https://www.brainiac.software/api/solar-design/horizon-shading-loss Keywords: before you finalise a solar PV design, horizon, records, latitude, longitude, elevation, times, beamPoa, beamLossFraction, skyDiffuseLossFraction, blockedHours, Estimate far-field horizon shading losses, horizon shading loss.
solar-design_module-layout-fitread-onlyMaximise the number of modules on a roof-face polygon with caller setbacks, orientation, gaps and obstruction polygons. Docs: https://www.brainiac.software/api/solar-design/module-layout-fit Keywords: before you finalise a solar PV design, roof, setback, module, gap, orientations, obstructions, gridOffsets, best, candidates, placements, Fit modules onto a roof polygon, module layout fit.
solar-design_module-spec-compareread-onlyNormalise and compare module datasheet values for efficiency, W/m², temperature-adjusted power, price per watt and warranty retention. Docs: https://www.brainiac.software/api/solar-design/module-spec-compare Keywords: before you finalise a solar PV design, modules, referenceCellTemp, ranking, Compare module datasheet metrics, module spec compare, Solar PV Design Calculations, solar design.
solar-design_nec-690-currentread-onlyCompute PV circuit maximum current and minimum conductor ampacity using NEC 690.8 125% factors for the selected code edition. Docs: https://www.brainiac.software/api/solar-design/nec-690-current Keywords: before you finalise a solar PV design, moduleIsc, edition, parallelStrings, continuousFactor, maxCircuitCurrent, minConductorAmpacity, minOcpdRating, perStringMaxCurrent, Compute NEC 690.8 PV circuit current, nec 690 current.
solar-design_pan-ond-parseread-onlyParse PVsyst PAN (module) and OND (inverter) text files into nested raw JSON and a normalised datasheet object. Docs: https://www.brainiac.software/api/solar-design/pan-ond-parse Keywords: before you finalise a solar PV design, fileType, content, raw, normalized, Parse PVsyst PAN or OND text files, pan ond parse, Solar PV Design Calculations.
solar-design_poa-irradiance-transposeread-onlyCompute plane-of-array irradiance with isotropic, Hay-Davies or Perez sky models and NREL SPA solar geometry from caller irradiance records. Docs: https://www.brainiac.software/api/solar-design/poa-irradiance-transpose Keywords: before you finalise a solar PV design, latitude, longitude, tilt, azimuth, records, elevation, albedo, model, pressurePa, temperatureC, deltaT, poa irradiance transpose.
solar-design_row-spacingread-onlyCompute row height, shadow gap, row pitch and ground coverage ratio that avoid row-to-row shading at a design sun position. Docs: https://www.brainiac.software/api/solar-design/row-spacing Keywords: before you finalise a solar PV design, moduleSlopeLength, tilt, arrayAzimuth, sun, designTimes, latitude, longitude, elevation, groundSlope, rowHeight, shadowGap, rowPitch, gcr, sunElevation.
solar-design_string-sizingread-onlyCompute minimum and maximum modules per series string and maximum parallel strings per MPPT from module temperature coefficients, site temperatures and inverter DC limits. Docs: https://www.brainiac.software/api/solar-design/string-sizing Keywords: before you finalise a solar PV design, module, site, inverter, vocAtTmin, vmpAtTmax, vmpAtTmin, iscAtTmax, maxModulesBySystemVoltage, minModulesByMppt, maxModulesByMpptUpper, recommendedRange, maxStringsPerMppt, feasible, Size PV module strings for an inverter MPPT.
solar-design_system-loss-stackread-onlyCombine individual loss percentages into a total system loss using PVWatts multiplicative derating, with optional defaults for missing categories. Docs: https://www.brainiac.software/api/solar-design/system-loss-stack Keywords: before you finalise a solar PV design, losses, useDefaultsForMissing, totalPercent, derate, items, Combine PVWatts system loss percentages, system loss stack.
solar-design_tariff-savingsread-onlyCompute bill savings from caller interval generation and load under a time-of-use tariff with export credit, net metering or no export value. Docs: https://www.brainiac.software/api/solar-design/tariff-savings Keywords: before you finalise a solar PV design, loadKwh, generationKwh, importPrice, intervalHours, exportMode, exportPrice, fixedCharges, demandCharge, billingPeriods, billWithoutPv, billWithPv, savings, importKwh, exportKwh.

Schemas: list_tools.

Similar MCP servers

More from software.brainiac

And 140 more from this publisher.

Official server.json
{
  "name": "software.brainiac/solar-design",
  "icons": [
    {
      "src": "https://www.brainiac.software/favicon-96x96.png",
      "sizes": [
        "96x96"
      ],
      "mimeType": "image/png"
    }
  ],
  "title": "BRAINIAC Solar PV Design Calculations",
  "$schema": "https://static.modelcontextprotocol.io/schemas/2025-12-11/server.schema.json",
  "remotes": [
    {
      "url": "https://www.brainiac.software/mcp/solar-design",
      "type": "streamable-http"
    }
  ],
  "version": "1.0.1",
  "websiteUrl": "https://www.brainiac.software",
  "description": "Paid Solar PV Design Calculations API via x402. Unpaid tool calls return 402."
}