Search / studio.crimp/crimp
Crimp
R0· no sign-inPlan DC electrical systems: find components, calculate circuits, check designs and create drafts.
v1.0.0 · active · website · descriptor JSON · versions
Search / studio.crimp/crimp
R0· no sign-inPlan DC electrical systems: find components, calculate circuits, check designs and create drafts.
v1.0.0 · active · website · descriptor JSON · versions
{
"mcpServers": {
"crimp": {
"type": "http",
"url": "https://crimp.studio/api/mcp"
}
}
}claude mcp add --transport http crimp https://crimp.studio/api/mcp[mcp_servers.crimp]
url = "https://crimp.studio/api/mcp"
{
"$schema": "https://opencode.ai/config.json",
"mcp": {
"crimp": {
"type": "remote",
"url": "https://crimp.studio/api/mcp",
"enabled": true
}
}
}{
"mcpServers": {
"crimp": {
"type": "http",
"url": "https://crimp.studio/api/mcp"
}
},
"deeplink": "cursor://anysphere.cursor-deeplink/mcp/install?name=crimp&config=eyJ0eXBlIjoiaHR0cCIsInVybCI6Imh0dHBzOi8vY3JpbXAuc3R1ZGlvL2FwaS9tY3AifQ%3D%3D"
}{
"servers": {
"crimp": {
"type": "http",
"url": "https://crimp.studio/api/mcp"
}
}
}{
"mcpServers": {
"crimp": {
"httpUrl": "https://crimp.studio/api/mcp"
}
}
}extensions:
"crimp":
enabled: true
name: "crimp"
type: streamable_http
uri: "https://crimp.studio/api/mcp"
timeout: 300
protocol.modernnewest supported version is 2025-11-25; 2026-07-28 not supported, older versions are deprecated until 2027-07-28protocol.statelessonly applies to 2026-07-28 serversprotocol.transportstreamable HTTPprotocol.list_ttlonly applies to 2026-07-28 serversauth.prm, auth.as_metadata, auth.cimdno remote uses OAuthauth.secret_in_urlno templated URLtools.descriptionsevery tool has a descriptiontools.description_lengthdescriptions are concisetools.schemasevery tool has an object input schematools.annotations5 of 5 tools declare readOnlyHint or destructiveHinttools.directory_hintsevery tool declares readOnlyHint, destructiveHint, idempotentHint and openWorldHinttools.token_costabout 5,824 tokens to load every tooltools.api_dumptools are not a one-to-one API dumpstability.changes2 tool changes in 30 daysstability.rug_pullno tool changed its meaning under the same namedeps.known_vulns, deps.mcp_sdk_version, deps.resolvableno npm or PyPI packagecreate_draftchangeddescriptionBuild and analyze a new reviewable Crimp draft from exact catalog IDs and structured connections, without an AI model call. Agent provides physical lengths and provenance; Crimp selects terminals, layout, wire and fuse suggestions. At most 10 counted equipment items, 40 components and 100 cables. Does not save, replace or publish a user's project. Retain assumptions and review findings before installation.
Build and analyze a Crimp planning draft from exact catalog IDs and structured connections, without an AI model call. Agent provides physical lengths and provenance; Crimp selects terminals, layout, wire and fuse suggestions. Display the exact returned reviewUrl as a clickable HTTPS link labeled Review schematic in Crimp; do not substitute a local HTML wrapper. The link opens a view-only preview; Edit a copy is a separate explicit action that creates a new local project. At most 10 counted equipment items, 40 components and 100 cables. Does not save, replace or publish a user's project. Retain assumptions and review findings before installation.
analyze_systemchangedinput schemaFull history: list_changes · trend: quality JSON.
Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed. How it is computed.
+dns-namespace +website +reachable +uptime-97% +updated-8d-ago -no-repository
Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed. How it is computed.
| remote | auth | reachable | uptime 30d | p50 | protocol | last ok |
|---|---|---|---|---|---|---|
https://crimp.studio/api/mcp streamable-http | none | yes | 97% | 487 ms | 2025-11-25 | 2026-10-19 |
analyze_systemread-only | Analyze an explicit current-schema System with Crimp's canonical sizing, diagnostics and energy engine. Read-only. Maximum 40 component nodes, 20 zones and 100 cables. Unknown fields, invalid references and other schema versions are rejected. Results preserve provisional currents, unknown fault protection and estimated inputs; no findings is not certification. No scenario sweep in v1. |
calculate_circuitread-only | Run the existing wire or DC-DC calculator deterministically. Every input field is required: use null for unknown numbers/options and an empty string for missing evidence. Unknown evidence stays unknown. kind=wire requires the wire input shape; kind=dc-dc requires the charger input shape. No fuse selection or installation certification. |
create_draftread-only | Build and analyze a Crimp planning draft from exact catalog IDs and structured connections, without an AI model call. Agent provides physical lengths and provenance; Crimp selects terminals, layout, wire and fuse suggestions. Display the exact returned reviewUrl as a clickable HTTPS link labeled Review schematic in Crimp; do not substitute a local HTML wrapper. The link opens a view-only preview; Edit a copy is a separate explicit action that creates a new local project. At most 10 counted equipment items, 40 components and 100 cables. Does not save, replace or publish a user's project. Retain assumptions and review findings before installation. |
get_componentread-only | Read one exact catalog component, including terminal IDs, electrical specs and known configuration. Catalog data does not verify an installed part or its protection evidence. |
search_componentsread-only | Search Crimp's catalog by name, manufacturer, model or ID. Returns stable catalog IDs and published component data; use get_component for terminals and full fields. Read-only; no AI model call. |
Schemas: list_tools.
{
"name": "studio.crimp/crimp",
"icons": [
{
"src": "https://crimp.studio/favicon.svg",
"sizes": [
"any"
],
"mimeType": "image/svg+xml"
}
],
"title": "Crimp",
"$schema": "https://static.modelcontextprotocol.io/schemas/2025-12-11/server.schema.json",
"remotes": [
{
"url": "https://crimp.studio/api/mcp",
"type": "streamable-http"
}
],
"version": "1.0.0",
"websiteUrl": "https://crimp.studio/developers/",
"description": "Plan DC electrical systems: find components, calculate circuits, check designs and create drafts."
}