Search / io.github.exquad/thecablecode
The Cable Code
R0· no sign-inDecode cable designations in 39 coding systems, design IEC-sized cables, find equivalents. No LLM.
v1.2.0 · active · website · descriptor JSON · versions
Search / io.github.exquad/thecablecode
R0· no sign-inDecode cable designations in 39 coding systems, design IEC-sized cables, find equivalents. No LLM.
v1.2.0 · active · website · descriptor JSON · versions
{
"mcpServers": {
"thecablecode": {
"type": "http",
"url": "https://thecablecode.com/mcp"
}
}
}claude mcp add --transport http thecablecode https://thecablecode.com/mcp[mcp_servers.thecablecode]
url = "https://thecablecode.com/mcp"
{
"$schema": "https://opencode.ai/config.json",
"mcp": {
"thecablecode": {
"type": "remote",
"url": "https://thecablecode.com/mcp",
"enabled": true
}
}
}{
"mcpServers": {
"thecablecode": {
"type": "http",
"url": "https://thecablecode.com/mcp"
}
},
"deeplink": "cursor://anysphere.cursor-deeplink/mcp/install?name=thecablecode&config=eyJ0eXBlIjoiaHR0cCIsInVybCI6Imh0dHBzOi8vdGhlY2FibGVjb2RlLmNvbS9tY3AifQ%3D%3D"
}{
"servers": {
"thecablecode": {
"type": "http",
"url": "https://thecablecode.com/mcp"
}
}
}{
"mcpServers": {
"thecablecode": {
"httpUrl": "https://thecablecode.com/mcp"
}
}
}extensions:
"thecablecode":
enabled: true
name: "thecablecode"
type: streamable_http
uri: "https://thecablecode.com/mcp"
timeout: 300
protocol.modernnewest supported version is 2025-11-25; 2026-07-28 not supported, older versions are deprecated until 2027-07-28protocol.statelessonly applies to 2026-07-28 serversprotocol.transportstreamable HTTPprotocol.list_ttlonly applies to 2026-07-28 serversauth.prm, auth.as_metadata, auth.cimdno remote uses OAuthauth.secret_in_urlno templated URLtools.descriptionsevery tool has a descriptiontools.description_lengthdescriptions are concisetools.schemasevery tool has an object input schematools.annotations4 of 4 tools declare readOnlyHint or destructiveHinttools.directory_hintsno tool declares all four of readOnlyHint, destructiveHint, idempotentHint and openWorldHint; missing: find_equivalents (destructiveHint); design_cable (destructiveHint); decode_cable_code (destructiveHint); …tools.token_costabout 1,429 tokens to load every tooltools.api_dumptools are not a one-to-one API dumpstability.changes, stability.rug_pulltool history recorded for 1 of the 7 days neededdeps.known_vulns, deps.mcp_sdk_version, deps.resolvableno npm or PyPI packagecheck_cablechangeddescription, input schemaCheck a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: IEC 60502-1 / -2, IEC 60228, HD 603 3-G / 5-G, HD 620 10-J / M / D / C / K, or "auto" for the standards the cable claims. Every rule with required, found, pass / fail / not checkable and its source (standard, edition, clause or table, page, how firmly seen). Deterministic, no LLM. A check against nominal rules, not a certificate or a type test.
Check a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: IEC 60502-1 / -2, IEC 60228, HD 603 3-G / 5-G, HD 620 10-J / M / D / C / K, BS 5467, BS 6724, BS 7846, BS 6622, or "auto" for the standards the cable claims. Every rule with required, found, pass / fail / not checkable and its source (standard, edition, clause or table, page, how firmly seen). Deterministic, no LLM. A check against nominal rules, not a certificate or a type test.
design_cablechangeddescription, input schemaDesign and size a power cable from a sentence (Turkish or English, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502-1 / -2, IEC 60228), the overall diameter, the DIN VDE 0276 designation and the decoder's reading of it; optional XML, DXF, SVG, CSV and GLB. Deterministic, no LLM; a nominal calculation, not a datasheet.
Design and size a power cable from a sentence (Turkish or English, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502-1 / -2, IEC 60228), the overall diameter, the DIN VDE 0276 designation and the decoder's reading of it; optional XML, DXF, SVG, CSV, GLB, STEP (3D CAD) and a PDF datasheet. Deterministic, no LLM; a nominal calculation, not a datasheet.
check_cableaddedCheck a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: IEC 60502-1 / -2, IEC 60228, HD 603 3-G / 5-G, HD 620 10-J / M / D / C / K, or "auto" for the standards the cable claims. Every rule with required, found, pass / fail / not checkable and its source (standard, edition, clause or table, page, how firmly seen). Deterministic, no LLM. A check against nominal rules, not a certificate or a type test.
find_equivalentsaddedFind the equivalents of a power cable in other countries' standards ("the Dutch equivalent of this Swedish cable"): the decoded cable is rebuilt under each target rule set (IEC 60502, HD 603, HD 620 sections J/M/D/C/K, BS 5467/6724/7846/6622, EN 50618, HD 627) with the same conductor, section, cores, voltage, screen, armour and sheath, then compared layer by layer with the source of every value. Verdict per standard: equivalent, close (with the differences) or none (with the reason), and the name in that country's letters where sourced. Deterministic, no LLM. Never a statement of interchangeability: the buyer's specification decides.
design_cableaddedDesign and size a power cable from a sentence (Turkish or English, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502-1 / -2, IEC 60228), the overall diameter, the DIN VDE 0276 designation and the decoder's reading of it; optional XML, DXF, SVG, CSV and GLB. Deterministic, no LLM; a nominal calculation, not a datasheet.
decode_cable_codechangeddescriptionDecode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 29 more of its 36 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM.
Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 32 more of its 39 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM.
Full history: list_changes · trend: quality JSON.
Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed. How it is computed.
+website +reachable +uptime-86% +updated-1d-ago -no-repository
Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed. How it is computed.
| remote | auth | reachable | uptime 30d | p50 | protocol | last ok |
|---|---|---|---|---|---|---|
https://thecablecode.com/mcp streamable-http | none | yes | 86% | 581 ms | 2025-11-25 | 2026-10-19 |
check_cableread-only | Check a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: IEC 60502-1 / -2, IEC 60228, HD 603 3-G / 5-G, HD 620 10-J / M / D / C / K, BS 5467, BS 6724, BS 7846, BS 6622, or "auto" for the standards the cable claims. Every rule with required, found, pass / fail / not checkable and its source (standard, edition, clause or table, page, how firmly seen). Deterministic, no LLM. A check against nominal rules, not a certificate or a type test. |
decode_cable_coderead-only | Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 32 more of its 39 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM. |
design_cableread-only | Design and size a power cable from a sentence (Turkish or English, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502-1 / -2, IEC 60228), the overall diameter, the DIN VDE 0276 designation and the decoder's reading of it; optional XML, DXF, SVG, CSV, GLB, STEP (3D CAD) and a PDF datasheet. Deterministic, no LLM; a nominal calculation, not a datasheet. |
find_equivalentsread-only | Find the equivalents of a power cable in other countries' standards ("the Dutch equivalent of this Swedish cable"): the decoded cable is rebuilt under each target rule set (IEC 60502, HD 603, HD 620 sections J/M/D/C/K, BS 5467/6724/7846/6622, EN 50618, HD 627) with the same conductor, section, cores, voltage, screen, armour and sheath, then compared layer by layer with the source of every value. Verdict per standard: equivalent, close (with the differences) or none (with the reason), and the name in that country's letters where sourced. Deterministic, no LLM. Never a statement of interchangeability: the buyer's specification decides. |
Schemas: list_tools.
{
"name": "io.github.exquad/thecablecode",
"title": "The Cable Code",
"$schema": "https://static.modelcontextprotocol.io/schemas/2025-12-11/server.schema.json",
"remotes": [
{
"url": "https://thecablecode.com/mcp",
"type": "streamable-http"
}
],
"version": "1.2.0",
"websiteUrl": "https://thecablecode.com/developers",
"description": "Decode cable designations in 39 coding systems, design IEC-sized cables, find equivalents. No LLM."
}