protogrid

Search / io.github.exquad/thecablecode

The Cable Code

R0· no sign-in

Decode cable designations in 39 coding systems, design IEC-sized cables, find equivalents. No LLM.

v1.2.0 · active · website · descriptor JSON · versions

An agent can connect right now, no human step.Remote endpoint, no authentication, reachable on the last probe.
Quality81new
Trust78of 100
Uptime, 30 days86%
Latency p50581 ms

Connect

8 clients · secrets stay placeholders
{
  "mcpServers": {
    "thecablecode": {
      "type": "http",
      "url": "https://thecablecode.com/mcp"
    }
  }
}
claude mcp add --transport http thecablecode https://thecablecode.com/mcp
[mcp_servers.thecablecode]
url = "https://thecablecode.com/mcp"
{
  "$schema": "https://opencode.ai/config.json",
  "mcp": {
    "thecablecode": {
      "type": "remote",
      "url": "https://thecablecode.com/mcp",
      "enabled": true
    }
  }
}
{
  "mcpServers": {
    "thecablecode": {
      "type": "http",
      "url": "https://thecablecode.com/mcp"
    }
  },
  "deeplink": "cursor://anysphere.cursor-deeplink/mcp/install?name=thecablecode&config=eyJ0eXBlIjoiaHR0cCIsInVybCI6Imh0dHBzOi8vdGhlY2FibGVjb2RlLmNvbS9tY3AifQ%3D%3D"
}
{
  "servers": {
    "thecablecode": {
      "type": "http",
      "url": "https://thecablecode.com/mcp"
    }
  }
}
{
  "mcpServers": {
    "thecablecode": {
      "httpUrl": "https://thecablecode.com/mcp"
    }
  }
}
extensions:
  "thecablecode":
    enabled: true
    name: "thecablecode"
    type: streamable_http
    uri: "https://thecablecode.com/mcp"
    timeout: 300

Quality 81 / 100new

protocol75 · weight 25
  • warn
    protocol.modernnewest supported version is 2025-11-25; 2026-07-28 not supported, older versions are deprecated until 2027-07-28
  • n/a
    protocol.statelessonly applies to 2026-07-28 servers
  • pass
    protocol.transportstreamable HTTP
  • n/a
    protocol.list_ttlonly applies to 2026-07-28 servers
authorizationn/a · weight 15
  • n/a
    auth.prm, auth.as_metadata, auth.cimdno remote uses OAuth
  • n/a
    auth.secret_in_urlno templated URL
tool hygiene86 · weight 30
  • pass
    tools.descriptionsevery tool has a description
  • pass
    tools.description_lengthdescriptions are concise
  • pass
    tools.schemasevery tool has an object input schema
  • pass
    tools.annotations4 of 4 tools declare readOnlyHint or destructiveHint
  • fail
    tools.directory_hintsno tool declares all four of readOnlyHint, destructiveHint, idempotentHint and openWorldHint; missing: find_equivalents (destructiveHint); design_cable (destructiveHint); decode_cable_code (destructiveHint); …
  • pass
    tools.token_costabout 1,429 tokens to load every tool
  • pass
    tools.api_dumptools are not a one-to-one API dump
stabilityn/a · weight 15
  • n/a
    stability.changes, stability.rug_pulltool history recorded for 1 of the 7 days needed
dependenciesn/a · weight 15
  • n/a
    deps.known_vulns, deps.mcp_sdk_version, deps.resolvableno npm or PyPI package

4 tools, about 1,429 tokens to load them all · tool set 3f7a2e58689c · tools last changed 2026-10-18 · checked 2026-10-19 11:27 UTC

Tool changes

  • check_cablechangeddescription, input schema
    before

    Check a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: IEC 60502-1 / -2, IEC 60228, HD 603 3-G / 5-G, HD 620 10-J / M / D / C / K, or "auto" for the standards the cable claims. Every rule with required, found, pass / fail / not checkable and its source (standard, edition, clause or table, page, how firmly seen). Deterministic, no LLM. A check against nominal rules, not a certificate or a type test.

    after · 94% of words in common

    Check a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: IEC 60502-1 / -2, IEC 60228, HD 603 3-G / 5-G, HD 620 10-J / M / D / C / K, BS 5467, BS 6724, BS 7846, BS 6622, or "auto" for the standards the cable claims. Every rule with required, found, pass / fail / not checkable and its source (standard, edition, clause or table, page, how firmly seen). Deterministic, no LLM. A check against nominal rules, not a certificate or a type test.

  • design_cablechangeddescription, input schema
    before

    Design and size a power cable from a sentence (Turkish or English, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502-1 / -2, IEC 60228), the overall diameter, the DIN VDE 0276 designation and the decoder's reading of it; optional XML, DXF, SVG, CSV and GLB. Deterministic, no LLM; a nominal calculation, not a datasheet.

    after · 94% of words in common

    Design and size a power cable from a sentence (Turkish or English, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502-1 / -2, IEC 60228), the overall diameter, the DIN VDE 0276 designation and the decoder's reading of it; optional XML, DXF, SVG, CSV, GLB, STEP (3D CAD) and a PDF datasheet. Deterministic, no LLM; a nominal calculation, not a datasheet.

  • check_cableadded

    Check a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: IEC 60502-1 / -2, IEC 60228, HD 603 3-G / 5-G, HD 620 10-J / M / D / C / K, or "auto" for the standards the cable claims. Every rule with required, found, pass / fail / not checkable and its source (standard, edition, clause or table, page, how firmly seen). Deterministic, no LLM. A check against nominal rules, not a certificate or a type test.

  • find_equivalentsadded

    Find the equivalents of a power cable in other countries' standards ("the Dutch equivalent of this Swedish cable"): the decoded cable is rebuilt under each target rule set (IEC 60502, HD 603, HD 620 sections J/M/D/C/K, BS 5467/6724/7846/6622, EN 50618, HD 627) with the same conductor, section, cores, voltage, screen, armour and sheath, then compared layer by layer with the source of every value. Verdict per standard: equivalent, close (with the differences) or none (with the reason), and the name in that country's letters where sourced. Deterministic, no LLM. Never a statement of interchangeability: the buyer's specification decides.

  • design_cableadded

    Design and size a power cable from a sentence (Turkish or English, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502-1 / -2, IEC 60228), the overall diameter, the DIN VDE 0276 designation and the decoder's reading of it; optional XML, DXF, SVG, CSV and GLB. Deterministic, no LLM; a nominal calculation, not a datasheet.

  • decode_cable_codechangeddescription
    before

    Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 29 more of its 36 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM.

    after · 91% of words in common

    Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 32 more of its 39 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM.

Full history: list_changes · trend: quality JSON.

Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed. How it is computed.

Trust 78 / 100

no-repository
provenance45
liveness94
freshness100
hygiene80

+website +reachable +uptime-86% +updated-1d-ago -no-repository

Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed. How it is computed.

Endpoints

remoteauthreachableuptime 30dp50protocollast ok
https://thecablecode.com/mcp streamable-httpnoneyes86%581 ms2025-11-252026-10-19

Tools (4)

check_cableread-onlyCheck a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: IEC 60502-1 / -2, IEC 60228, HD 603 3-G / 5-G, HD 620 10-J / M / D / C / K, BS 5467, BS 6724, BS 7846, BS 6622, or "auto" for the standards the cable claims. Every rule with required, found, pass / fail / not checkable and its source (standard, edition, clause or table, page, how firmly seen). Deterministic, no LLM. A check against nominal rules, not a certificate or a type test.
decode_cable_coderead-onlyDecode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 32 more of its 39 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM.
design_cableread-onlyDesign and size a power cable from a sentence (Turkish or English, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502-1 / -2, IEC 60228), the overall diameter, the DIN VDE 0276 designation and the decoder's reading of it; optional XML, DXF, SVG, CSV, GLB, STEP (3D CAD) and a PDF datasheet. Deterministic, no LLM; a nominal calculation, not a datasheet.
find_equivalentsread-onlyFind the equivalents of a power cable in other countries' standards ("the Dutch equivalent of this Swedish cable"): the decoded cable is rebuilt under each target rule set (IEC 60502, HD 603, HD 620 sections J/M/D/C/K, BS 5467/6724/7846/6622, EN 50618, HD 627) with the same conductor, section, cores, voltage, screen, armour and sheath, then compared layer by layer with the source of every value. Verdict per standard: equivalent, close (with the differences) or none (with the reason), and the name in that country's letters where sourced. Deterministic, no LLM. Never a statement of interchangeability: the buyer's specification decides.

Schemas: list_tools.

Similar MCP servers

Official server.json
{
  "name": "io.github.exquad/thecablecode",
  "title": "The Cable Code",
  "$schema": "https://static.modelcontextprotocol.io/schemas/2025-12-11/server.schema.json",
  "remotes": [
    {
      "url": "https://thecablecode.com/mcp",
      "type": "streamable-http"
    }
  ],
  "version": "1.2.0",
  "websiteUrl": "https://thecablecode.com/developers",
  "description": "Decode cable designations in 39 coding systems, design IEC-sized cables, find equivalents. No LLM."
}