protogrid

Search / com.structomat/steel

Structomat

R0· no sign-in

Steel structures: 3D frame analysis, AISC checks, IFC cost, tonnage, connections, LGS house design.

v1.8.1 · active · website · descriptor JSON · versions

An agent can connect right now, no human step.Remote endpoint, no authentication, reachable on the last probe.
Quality85good
Trust83of 100
Uptime, 30 days100%
Latency p50398 msp95 677 ms

Connect

8 clients · secrets stay placeholders
Add to CursorAdd to VS Codeopens the client, which asks before adding the server
{
  "mcpServers": {
    "steel": {
      "type": "http",
      "url": "https://structomat.com/mcp/"
    }
  }
}
claude mcp add --transport http steel https://structomat.com/mcp/
[mcp_servers.steel]
url = "https://structomat.com/mcp/"
{
  "$schema": "https://opencode.ai/config.json",
  "mcp": {
    "steel": {
      "type": "remote",
      "url": "https://structomat.com/mcp/",
      "enabled": true
    }
  }
}
{
  "mcpServers": {
    "steel": {
      "type": "http",
      "url": "https://structomat.com/mcp/"
    }
  },
  "deeplink": "cursor://anysphere.cursor-deeplink/mcp/install?name=steel&config=eyJ0eXBlIjoiaHR0cCIsInVybCI6Imh0dHBzOi8vc3RydWN0b21hdC5jb20vbWNwLyJ9"
}
{
  "servers": {
    "steel": {
      "type": "http",
      "url": "https://structomat.com/mcp/"
    }
  },
  "deeplink": "vscode:mcp/install?%7B%22name%22%3A%22steel%22%2C%22type%22%3A%22http%22%2C%22url%22%3A%22https%3A%2F%2Fstructomat.com%2Fmcp%2F%22%7D"
}
{
  "mcpServers": {
    "steel": {
      "httpUrl": "https://structomat.com/mcp/"
    }
  }
}
extensions:
  "steel":
    enabled: true
    name: "steel"
    type: streamable_http
    uri: "https://structomat.com/mcp/"
    timeout: 300

Quality 85 / 100good

protocol75 · weight 25
  • warn
    protocol.modernnewest supported version is 2025-06-18; 2026-07-28 not supported, older versions are deprecated until 2027-07-28
  • n/a
    protocol.statelessonly applies to 2026-07-28 servers
  • pass
    protocol.transportstreamable HTTP
  • n/a
    protocol.list_ttlonly applies to 2026-07-28 servers
authorizationn/a · weight 15
  • n/a
    auth.prm, auth.as_metadata, auth.cimdno remote uses OAuth
  • n/a
    auth.secret_in_urlno templated URL
tool hygiene94 · weight 30
  • pass
    tools.descriptionsevery tool has a description
  • warn
    tools.description_length4 tools have descriptions over 1,024 characters, which crowds the context
  • pass
    tools.schemasevery tool has an object input schema
  • pass
    tools.annotations11 of 11 tools declare readOnlyHint or destructiveHint
  • pass
    tools.directory_hintsevery tool declares readOnlyHint, destructiveHint, idempotentHint and openWorldHint
  • pass
    tools.token_costabout 7,928 tokens to load every tool
  • pass
    tools.api_dumptools are not a one-to-one API dump
  • pass
    tools.hidden_textno hidden text in tool names, descriptions, schemas or annotations
  • pass
    tools.poisoningno instructions aimed at the model in tool definitions
stability83 · weight 15
  • warn
    stability.changes31 tool changes in 30 days
  • pass
    stability.rug_pullno tool changed its meaning under the same name
  • pass
    stability.new_linksno tool change named a new site
dependenciesn/a · weight 15
  • n/a
    deps.known_vulns, deps.mcp_sdk_version, deps.resolvableno npm or PyPI package

11 tools, about 7,928 tokens to load them all · tool set 9afbc5e70c90 · tools last changed 2026-11-21 · checked 2026-11-29 14:52 UTC

Definition changes

  • design_lgs_framingadded

    Preliminary design of the cold-formed steel (light gauge steel, LGS) framing of a single-storey house with a gable roof on a concrete slab, in Canada: NBC 2020 Part 4 loads (snow, wind, earthquake when Sa values are given), members and screw connections to AISI S100-16 with the Canadian Appendix B (CSA S136) and AISI S240-20, Limit States Design. Frames the house (studs and tracks at 406 or 610 mm in line with Fink roof trusses, box headers with jack and king studs over every opening, full-height gable walls, bridging), analyses it and checks every member group and connection: truss chords, webs, heel and ridge gusset plates and screw groups, studs under axial load and wind, headers, gable wall studs, Type I OSB shear walls, the roof diaphragm, overall uplift and overturning. Sections not given are sized automatically (lightest SSMA S-section that passes; 43 mil and thicker studs). Returns the sections, piece count and steel mass by section, the governing utilisation ratio of each group and the ratio of every check, and which checks are conditional. Rectangular plan only, no interior load-bearing walls, roof 10 to 45 degrees, truss span 4 to 14 m, low building for wind. When wind uplift or overturning exceeds 0.9 x dead load the result says that anchorage to the foundation is required. Anchors, hold-down products, foundations, sheathing products and roll-former data are not designed. Nothing is stored. Preliminary, not signed.

  • list_serviceschangedinput schema
  • check_connectionadded

    Instant utilisation (demand/capacity) of a standard steel connection under the given member-end forces, from capacities precomputed with finite-element connection analysis to AISC 360-16 LRFD (S275 steel, grade 8.8 bolts, C30/37 concrete). Returns the utilisation, the governing component (and the governing plate, weld or bolt group) and warnings. Call without "template" to list the templates and sizes. Forces are member-end forces at the analysis node, i.e. at the centreline of the supporting column or main beam (as a frame analysis gives them), not at its face; the capacities already include the offset. Only for a joint where no other member frames in: if anything else connects at the node, the result does not apply (ask for a connection design instead). For a first idea of a connection; a design for construction needs a checked calculation.

  • draft_project_requestadded

    Prepare an e-mail to Structomat ([email protected]) describing a project, ready for the user to review and send. This tool sends nothing and stores nothing; it returns the draft text and a mailto link.

  • estimate_steel_costadded

    Cost of fabricating and erecting a steel structure, worked out part by part from its IFC model: every part, hole, weld and lift is timed as a shop or site operation and priced at the region's employer labour cost, steel price and crane rate. Returns the cost floor (total, per tonne, per m2 of floor) with its breakdown, the published market band next to it and the gap, the process groups that drive the cost, the ten costliest parts with their IFC ids, a programme from shop drawings to erection in working days, upfront embodied carbon (modules A1-A5: steel production, fabrication, delivery, erection), and what an example design review (lighter sections, fewer plate fittings) would save in cost and carbon. Regions: UK, DE (Germany), US, AU, or own rates in any currency. Give the IFC as a public link (ifc_url, up to 30 MB) or as its text (ifc_text, up to 12 MB), or sample=true for a sample 18 x 30 m portal frame shed. It is the engine of Structomat's free Steel Cost Estimator page, which shows the same result with a 3D cost heat map when the same IFC is dropped on it. An estimate, not a quote. The IFC is read in memory and not stored.

  • check_steel_membersadded

    Preliminary strength check of steel members to AISC 360-16 LRFD under the forces you give: available strengths and the demand-to-capacity ratio D/C of each member, the governing limit state and every step with its clause. Covers compression (flexural, torsional and local buckling, E3/E4/E7), tension yielding (D2), bending about both axes with lateral-torsional and local buckling (F2, F3, F6, F7, F8; Cb given or from the moment diagram, 1.0 for cantilevers), shear (G2.1, G4, G5, G6) and the H1-1 interaction, for I-sections (IPE, HEA, HEB, or dimensions: rolled when a root radius r > 0 is given, welded when r = 0 or "built_up": true), rectangular and square hollow sections (RHS/SHS) and round hollow sections (CHS), HSS design wall thickness 0.93t (B4.2). Steel grades ASTM A992, A36, A572 Gr. 50, A500 Gr. C, A53 Gr. B, or Fy; EN S235-S355 (EN 10025, EN 10219 as S..H) are checked with the AISC equations by analogy, since AISC 360-16 approves ASTM materials (A3.1a). The forces are taken as given: they must include second-order effects, from the direct analysis method of Chapter C or, with K from a stability analysis, the effective length method (analyze_frame gives elastic second-order forces without notional loads or stiffness reduction, and its result already has a member check of every member); the effective lengths are yours. Not covered (reported): webs noncompact or slender in flexure for I-sections, torsion, net-section rupture, connections, seismic provisions, fire. Up to 50 members per call; nothing is stored.

  • analyze_frameadded

    Runs a 3D finite-element frame analysis and returns the numbers: equilibrium check, largest deflection along the members, largest joint displacement and sway in X and Y, every support reaction, the axial force, shears and moments of every member (the envelope with the governing combination when there are several), and natural periods with mass participation (modal analysis); linear or second order (P-Delta). The model is either a template (a pitched portal frame building, an open mono-pitch canopy, or a multi-storey frame, from a few dimensions, sections and loads) or a full model in JSON (nodes, members, sections, supports, loads, combinations). It is solved by the code of Structomat's free 3D frame analysis page, so the result also has a link that shows the same model and results in 3D (deflected shape, force diagrams, mode shapes). Use it to check a frame, compare sections or see how loads flow, and run it again with changed sections or loads. The result also has a preliminary member check to AISC 360-16 LRFD (results.member_check): the demand-to-capacity ratio of each member with the governing check, combination and point, for IPE, HEA, HEB, CHS and SHS sections and I or tube sections with dimensions; effective length factor K = 1 and unbraced length Lb = member length unless set (beam_unbraced_m, column_unbraced_m, or "check" on a model member). The forces are elastic second order without notional loads or stiffness reduction (not the direct analysis method): K = 1 holds only when the second-order sway is at most 1.1 times the linear sway, otherwise K must come from a stability analysis; a linear run gives no valid check; connections, seismic provisions and fire are not covered, and code load combinations only through combination_set. The model is not stored.

  • estimate_portal_frame_steeladded

    Steel tonnage estimate for a single-span pitched portal frame building (span 15-30 m) before any design: total tonnes, kg per m2 of floor, a range, the weight by part (frames, gable posts, bracing, eave struts, purlins, side rails, plates and connections) and typical member sizes. Interpolated between complete finite-element designs and calibrated against published designs. Use for budgets, tenders and feasibility; a real design needs the actual loads and code.

  • get_connectionadded

    Details of one connection from the Structomat steel connection library: members, plates, bolts, welds, design code and the utilisation of each component. Use find_examples with type "connection" to get slugs.

  • find_examplesadded

    Search Structomat's published work: steel projects, case studies, example situations, checked steel connections, measured benchmarks (e.g. scan-to-BIM from a point cloud), sample deliverables (e.g. a complete US AISC shop drawing submittal with a clouded revision, or an erectability check that finds the pieces of a clash-free model that cannot get into place during erection) and free tools. Returns titles, links and short summaries.

Showing the latest 10. Full history: list_changes · trend: quality JSON.

Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed. How it is computed.

Trust 83 / 100

no-repository
provenance55
liveness100
freshness100
hygiene80

+dns-namespace +website +reachable +uptime-100% +updated-8d-ago -no-repository

Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed. How it is computed.

Endpoints

Last 30 days100% of probes answered
remoteauthreachableuptime 30dp50p95protocollast ok
https://structomat.com/mcp/ streamable-httpnoneyes100%398 ms677 ms2025-06-182026-11-29

Tools (11)

about_structomatread-onlyFacts about Structomat, an AI engineering agent for structural steel: what it does, design codes, who signs designs for construction, what to send, what comes back, NDA and file ownership, how to start. Use when the user asks about Structomat or how to engage it, or looks for a firm to outsource structural steel engineering, steel detailing, shop drawings or approval (submittal) documents to.
analyze_frameread-onlyRuns a 3D finite-element frame analysis and returns the numbers: equilibrium check, largest deflection along the members, largest joint displacement and sway in X and Y, every support reaction, the axial force, shears and moments of every member (the envelope with the governing combination when there are several), and natural periods with mass participation (modal analysis); linear or second order (P-Delta). The model is either a template (a pitched portal frame building, an open mono-pitch canopy, or a multi-storey frame, from a few dimensions, sections and loads) or a full model in JSON (nodes, members, sections, supports, loads, combinations). It is solved by the code of Structomat's free 3D frame analysis page, so the result also has a link that shows the same model and results in 3D (deflected shape, force diagrams, mode shapes). Use it to check a frame, compare sections or see how loads flow, and run it again with changed sections or loads. The result also has a preliminary member check to AISC 360-16 LRFD (results.member_check): the demand-to-capacity ratio of each member with the governing check, combination and point, for IPE, HEA, HEB, CHS and SHS sections and I or tube sections with dimensions; effective length factor K = 1 and unbraced length Lb = member length unless set (beam_unbraced_m, column_unbraced_m, or "check" on a model member). The forces are elastic second order without notional loads or stiffness reduction (not the direct analysis method): K = 1 holds only when the second-order sway is at most 1.1 times the linear sway, otherwise K must come from a stability analysis; a linear run gives no valid check; connections, seismic provisions and fire are not covered, and code load combinations only through combination_set. The model is not stored.
check_connectionread-onlyInstant utilisation (demand/capacity) of a standard steel connection under the given member-end forces, from capacities precomputed with finite-element connection analysis to AISC 360-16 LRFD (S275 steel, grade 8.8 bolts, C30/37 concrete). Returns the utilisation, the governing component (and the governing plate, weld or bolt group) and warnings. Call without "template" to list the templates and sizes. Forces are member-end forces at the analysis node, i.e. at the centreline of the supporting column or main beam (as a frame analysis gives them), not at its face; the capacities already include the offset. Only for a joint where no other member frames in: if anything else connects at the node, the result does not apply (ask for a connection design instead). For a first idea of a connection; a design for construction needs a checked calculation.
check_steel_membersread-onlyPreliminary strength check of steel members to AISC 360-16 LRFD under the forces you give: available strengths and the demand-to-capacity ratio D/C of each member, the governing limit state and every step with its clause. Covers compression (flexural, torsional and local buckling, E3/E4/E7), tension yielding (D2), bending about both axes with lateral-torsional and local buckling (F2, F3, F6, F7, F8; Cb given or from the moment diagram, 1.0 for cantilevers), shear (G2.1, G4, G5, G6) and the H1-1 interaction, for I-sections (IPE, HEA, HEB, or dimensions: rolled when a root radius r > 0 is given, welded when r = 0 or "built_up": true), rectangular and square hollow sections (RHS/SHS) and round hollow sections (CHS), HSS design wall thickness 0.93t (B4.2). Steel grades ASTM A992, A36, A572 Gr. 50, A500 Gr. C, A53 Gr. B, or Fy; EN S235-S355 (EN 10025, EN 10219 as S..H) are checked with the AISC equations by analogy, since AISC 360-16 approves ASTM materials (A3.1a). The forces are taken as given: they must include second-order effects, from the direct analysis method of Chapter C or, with K from a stability analysis, the effective length method (analyze_frame gives elastic second-order forces without notional loads or stiffness reduction, and its result already has a member check of every member); the effective lengths are yours. Not covered (reported): webs noncompact or slender in flexure for I-sections, torsion, net-section rupture, connections, seismic provisions, fire. Up to 50 members per call; nothing is stored.
design_lgs_framingread-onlyPreliminary design of the cold-formed steel (light gauge steel, LGS) framing of a single-storey house with a gable roof on a concrete slab, in Canada: NBC 2020 Part 4 loads (snow, wind, earthquake when Sa values are given), members and screw connections to AISI S100-16 with the Canadian Appendix B (CSA S136) and AISI S240-20, Limit States Design. Frames the house (studs and tracks at 406 or 610 mm in line with Fink roof trusses, box headers with jack and king studs over every opening, full-height gable walls, bridging), analyses it and checks every member group and connection: truss chords, webs, heel and ridge gusset plates and screw groups, studs under axial load and wind, headers, gable wall studs, Type I OSB shear walls, the roof diaphragm, overall uplift and overturning. Sections not given are sized automatically (lightest SSMA S-section that passes; 43 mil and thicker studs). Returns the sections, piece count and steel mass by section, the governing utilisation ratio of each group and the ratio of every check, and which checks are conditional. Rectangular plan only, no interior load-bearing walls, roof 10 to 45 degrees, truss span 4 to 14 m, low building for wind. When wind uplift or overturning exceeds 0.9 x dead load the result says that anchorage to the foundation is required. Anchors, hold-down products, foundations, sheathing products and roll-former data are not designed. Nothing is stored. Preliminary, not signed.
draft_project_requestread-onlyPrepare an e-mail to Structomat ([email protected]) describing a project, ready for the user to review and send. This tool sends nothing and stores nothing; it returns the draft text and a mailto link.
estimate_portal_frame_steelread-onlySteel tonnage estimate for a single-span pitched portal frame building (span 15-30 m) before any design: total tonnes, kg per m2 of floor, a range, the weight by part (frames, gable posts, bracing, eave struts, purlins, side rails, plates and connections) and typical member sizes. Interpolated between complete finite-element designs and calibrated against published designs. Use for budgets, tenders and feasibility; a real design needs the actual loads and code.
estimate_steel_costread-onlyCost of fabricating and erecting a steel structure, worked out part by part from its IFC model: every part, hole, weld and lift is timed as a shop or site operation and priced at the region's employer labour cost, steel price and crane rate. Returns the cost floor (total, per tonne, per m2 of floor) with its breakdown, the published market band next to it and the gap, the process groups that drive the cost, the ten costliest parts with their IFC ids, a programme from shop drawings to erection in working days, upfront embodied carbon (modules A1-A5: steel production, fabrication, delivery, erection), and what an example design review (lighter sections, fewer plate fittings) would save in cost and carbon. Regions: UK, DE (Germany), US, AU, or own rates in any currency. Give the IFC as a public link (ifc_url, up to 30 MB) or as its text (ifc_text, up to 12 MB), or sample=true for a sample 18 x 30 m portal frame shed. It is the engine of Structomat's free Steel Cost Estimator page, which shows the same result with a 3D cost heat map when the same IFC is dropped on it. An estimate, not a quote. The IFC is read in memory and not stored.
find_examplesread-onlySearch Structomat's published work: steel projects, case studies, example situations, checked steel connections, measured benchmarks (e.g. scan-to-BIM from a point cloud), sample deliverables (e.g. a complete US AISC shop drawing submittal with a clouded revision, or an erectability check that finds the pieces of a clash-free model that cannot get into place during erection) and free tools. Returns titles, links and short summaries.
get_connectionread-onlyDetails of one connection from the Structomat steel connection library: members, plates, bolts, welds, design code and the utilisation of each component. Use find_examples with type "connection" to get slugs.
list_servicesread-onlyStructomat services (analysis & design, connection design, shop drawings, erectability check of a steel model before erection, automation consulting, custom tools) with what the client sends and what comes back.

Schemas: list_tools.

Similar MCP servers

Official server.json
{
  "name": "com.structomat/steel",
  "icons": [
    {
      "src": "https://structomat.com/wp-content/uploads/2026/09/structomat-mark-300x300.png",
      "sizes": [
        "300x300"
      ],
      "mimeType": "image/png"
    }
  ],
  "title": "Structomat",
  "$schema": "https://static.modelcontextprotocol.io/schemas/2025-12-11/server.schema.json",
  "remotes": [
    {
      "url": "https://structomat.com/mcp/",
      "type": "streamable-http"
    }
  ],
  "version": "1.8.1",
  "websiteUrl": "https://structomat.com/about/",
  "description": "Steel structures: 3D frame analysis, AISC checks, IFC cost, tonnage, connections, LGS house design."
}