protogrid

Search / com.engscript/mcp

EngScript Engineering MCP

R0· no sign-in

Engineering calculation MCP server for oil and gas engineering applications.

v1.0.0 · active · descriptor JSON · versions

An agent can connect right now, no human step.Remote endpoint, no authentication, reachable on the last probe.
Quality73needs work
Trust77of 100
Uptime, 30 days100%
Latency p50461 ms

Connect

8 clients · secrets stay placeholders
{
  "mcpServers": {
    "engscript": {
      "type": "http",
      "url": "https://engscript.com/mcp"
    }
  }
}
claude mcp add --transport http engscript https://engscript.com/mcp
[mcp_servers.engscript]
url = "https://engscript.com/mcp"
{
  "$schema": "https://opencode.ai/config.json",
  "mcp": {
    "engscript": {
      "type": "remote",
      "url": "https://engscript.com/mcp",
      "enabled": true
    }
  }
}
{
  "mcpServers": {
    "engscript": {
      "type": "http",
      "url": "https://engscript.com/mcp"
    }
  },
  "deeplink": "cursor://anysphere.cursor-deeplink/mcp/install?name=engscript&config=eyJ0eXBlIjoiaHR0cCIsInVybCI6Imh0dHBzOi8vZW5nc2NyaXB0LmNvbS9tY3AifQ%3D%3D"
}
{
  "servers": {
    "engscript": {
      "type": "http",
      "url": "https://engscript.com/mcp"
    }
  }
}
{
  "mcpServers": {
    "engscript": {
      "httpUrl": "https://engscript.com/mcp"
    }
  }
}
extensions:
  "engscript":
    enabled: true
    name: "engscript"
    type: streamable_http
    uri: "https://engscript.com/mcp"
    timeout: 300

Quality 73 / 100needs work

protocol75 · weight 25
  • warn
    protocol.modernnewest supported version is 2025-06-18; 2026-07-28 not supported, older versions are deprecated until 2027-07-28
  • n/a
    protocol.statelessonly applies to 2026-07-28 servers
  • pass
    protocol.transportstreamable HTTP
  • n/a
    protocol.list_ttlonly applies to 2026-07-28 servers
authorizationn/a · weight 15
  • n/a
    auth.prm, auth.as_metadata, auth.cimdno remote uses OAuth
  • n/a
    auth.secret_in_urlno templated URL
tool hygiene57 · weight 30
  • pass
    tools.descriptionsevery tool has a description
  • pass
    tools.description_lengthdescriptions are concise
  • pass
    tools.schemasevery tool has an object input schema
  • fail
    tools.annotationsno tool declares readOnlyHint or destructiveHint, so clients cannot tell safe calls from risky ones
  • fail
    tools.directory_hintsno tool declares all four of readOnlyHint, destructiveHint, idempotentHint and openWorldHint; missing: CARBON (readOnlyHint, destructiveHint, idempotentHint, openWorldHint); PTV (readOnlyHint, destructiveHint, idempotentHint, openWorldHint); MtoV (readOnlyHint, destructiveHint, idempotentHint, openWorldHint); …
  • fail
    tools.token_costabout 27,082 tokens to load every tool, a large share of an agent's context
  • pass
    tools.api_dumptools are not a one-to-one API dump
stability100 · weight 15
  • pass
    stability.changes2 tool changes in 30 days
  • pass
    stability.rug_pullno tool changed its meaning under the same name
dependenciesn/a · weight 15
  • n/a
    deps.known_vulns, deps.mcp_sdk_version, deps.resolvableno npm or PyPI package

60 tools, about 27,082 tokens to load them all · tool set bf83ca275a93 · tools last changed 2026-10-11 · checked 2026-10-19 10:52 UTC

Tool changes

  • PINCHSOLVERadded

    Pinch analysis (minimum utilities, pinch temperatures, composite curves, grand composite curve) and heat exchanger network design by optimization solver

  • PINCHMANUALadded

    Pinch analysis (minimum utilities, pinch temperatures, composite curves, grand composite curve) and heat exchanger network design by manual tick-off heuristic

Full history: list_changes · trend: quality JSON.

Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed. How it is computed.

Trust 77 / 100

no-repository
provenance45
liveness100
freshness85
hygiene80

+dns-namespace +reachable +uptime-100% ~updated-66d-ago -no-repository

Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed. How it is computed.

Endpoints

remoteauthreachableuptime 30dp50protocollast ok
https://engscript.com/mcp streamable-httpnoneyes100%461 ms2025-06-182026-10-19

Tools (60)

advDVRAdvanced Data Validation and Reconciliation including gross error detection and elimation
advECONOMICAdvanced Economic analysis with inflation, depreciation, and tax: NPV, IRR, Simple Payback, Profitability Index, NCF
BALANCEGeneral mass/energy balance solver using GEKKO
CARBONCalculate thermodynamic properties of hydrocarbon mixture. Supports hydrocarbons and non-hydrocarbon chemicals (PR EOS flash calculation).
COMPPOLYEFFCalculate polytropic efficiency of compressor
CTWRCAPACooling tower capacity evaluation
CTWRCAPADSNTSTCooling tower capacity evaluation: design vs test
CTWREVAPORCooling tower evaporation rate: mass removal rate (MR) and heat removal rate (QR)
CTWRLGCooling tower L/G ratio calculation
CTWRNTUCooling tower NTU and characteristic C value calculation
CVGASCalculate gas control valve Cv and Kv from flow conditions
CVLIQCalculate liquid control valve Cv and Kv from flow conditions
CVSTEAMCalculate steam control valve Cv and Kv from flow conditions
DESUPERHEATERCalculate boiler feed water flow and total flow from pressure and temperature reduction through desuperheater. Also returns the inlet/outlet/BFW specific enthalpies (h_in, h_out, h_bfw) used in the mass balance, always in Btu/lb.
DVRData Validation and Reconciliation
ECONOMICEconomic analysis: NPV, IRR, Simple Payback, Profitability Index, EAC
EMISSIONFACTORCalculate CO2 emission conversion factor from gas composition
FLUEGASCalculate enthalpy of flue gas from composition
FORMULAGeneric formula calculator with unit conversion and IF-THEN-ELSE
FUELGASCalculate MW, LHV and HHV of fuel gas from composition
GN2DEPRESSCalculate depressurization gas volume and hold time for gaseous nitrogen storage vessel
HEXRFHeat exchanger fouling resistance back-calculation from shell/tube-side operating conditions.
HPADEPRESSCalculate depressurization gas volume and hold time for high pressure air storage vessel
HTRINOUTEFFCalculate fired heater heat duty and efficiency from inlet/outlet conditions and composition
HTRLOSSEFFCalculate fired heater loss efficiency from ambient temperature, stack gas temperature and excess oxygen
LMTDCalculate LMTD of heat exchanger
LN2DEPRESSCalculate depressurization gas volumn abd hold time and saturation temperature for liquid nitrogen storage vessel
MIXTUREPrimary thermodynamic property calculator. Use this tool first for all mixture property calculations. Supports hydrocarbons and non-hydrocarbon chemicals (PR EOS flash calculation).
MtoVConvert mass flow rate to volumetric flow rate at standard condition
ORIFICEGASGas orifice sizing / differential pressure / flow rate calculation based on ISO 5167 orifice. Exactly ONE of [M, dP, D2] must be set to '?' — that variable will be calculated.
ORIFICELIQLiquid orifice sizing / differential pressure / flow rate calculation based on ISO 5167 orifice. Exactly ONE of [M, dP, D2] must be set to '?' — that variable will be calculated.
PINCHMANUALPinch analysis (minimum utilities, pinch temperatures, composite curves, grand composite curve) and heat exchanger network design by manual tick-off heuristic
PINCHSOLVERPinch analysis (minimum utilities, pinch temperatures, composite curves, grand composite curve) and heat exchanger network design by optimization solver
PIPEAIRCalculate compressed air pipe sizing: pipe diameter, velocity, pressure drop
PIPEFFCalculate Darcy friction factor based on Reynolds number and pipe roughness
PIPEFLOWGASCalculate isothermal gas pipe flow: density, volumetric flow rate, mass flow rate from pressure drop
PIPEFLOWLIQCalculate liquid pipe flow: volumetric flow rate and mass flow rate from pressure drop
PIPEINSULCalculate optimal pipe insulation thickness to limit outer surface temperature (burn protection) and minimise heat loss. Uses cylindrical heat conduction + external convection model, solved via scipy.optimize.brentq. Returns exact minimum thickness and nearest commercial 5 mm step.
PIPENITROGENCalculate nitrogen pipe sizing: pipe diameter, velocity, pressure drop
PIPESTEAMCalculate steam pipe sizing: pipe diameter, velocity, pressure drop
PIPEWATERCalculate water pipe sizing: pipe diameter, velocity, pressure drop
PmeanCalculate mean pressure between inlet and outlet
PSVGASCalculate required PSV (pressure safety valve) relief area for gas/vapor service per API 520
PSVLIQCalculate required PSV (pressure safety valve) relief area for liquid service per API 520
PSVSTEAMCalculate required PSV (pressure safety valve) relief area for steam service per API 520
PSYCHROMETRICPsychrometric properties of moist air
PTVCalculate gas molar volume using equation of state
PUMPBHPCalculate pump brake horsepower
REFRIGERANTCalculate refrigerant thermodynamic properties using CoolProp. Provide Fluid name and any 2 state variables from: T, P, rho, H, S, U. Returns all remaining properties: T, P, rho, H, S, U, Cp, Cv, viscosity, conductivity, molecular weight.
SOLVESolve nonlinear equations with unknown variables using fsolve
STEAMCalculate thermodynamic and transport properties of steam based on IAPWS
STEAMFLASHCalculate flash steam flow from pressure reduction
STEAMLEAKCalculate steam leak mass flow and flow condition (CHOKED / SUBCRITICAL) based on upstream and downstream conditions
STEAMPHCalculate mass flow from pin-hole on the steam piping
STGEFFCalculate multistage steam turbine isentropic efficiency
STMDEPRESSCalculate depressurization steam volumn and hold time for steam accumulator
TBNEFFCalculate steam turbine isentropic efficiency
VENTURIGASGas Venturi tube sizing / differential pressure / flow rate calculation based on ISO 5167 Venturi meter (as cast convergent venturi tube). Exactly ONE of [M, dP, D2] must be set to '?' — that variable will be calculated.
VENTURILIQLiquid Venturi tube sizing / differential pressure / flow rate calculation based on ISO 5167 Venturi meter (as cast convergent venturi tube). Exactly ONE of [M, dP, D2] must be set to '?' — that variable will be calculated.
VtoMConvert volumetric flow rate to mass flow rate at standard condition and normal condition Sm3/hr, Nm3/hr, SCFH

Schemas: list_tools.

Similar MCP servers

Official server.json
{
  "name": "com.engscript/mcp",
  "title": "EngScript Engineering MCP",
  "$schema": "https://static.modelcontextprotocol.io/schemas/2025-12-11/server.schema.json",
  "remotes": [
    {
      "url": "https://engscript.com/mcp",
      "type": "streamable-http"
    }
  ],
  "version": "1.0.0",
  "description": "Engineering calculation MCP server for oil and gas engineering applications."
}