SparkQuote NEC calculators
R0· no sign-inNEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
v1.0.1 · active · website · descriptor JSON · versions
Search / ai.sparkquote/nec-calculators
R0· no sign-inNEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
v1.0.1 · active · website · descriptor JSON · versions
{
"mcpServers": {
"nec-calculators": {
"type": "http",
"url": "https://sparkquote.ai/mcp"
}
}
}claude mcp add --transport http nec-calculators https://sparkquote.ai/mcp[mcp_servers.nec-calculators]
url = "https://sparkquote.ai/mcp"
{
"$schema": "https://opencode.ai/config.json",
"mcp": {
"nec-calculators": {
"type": "remote",
"url": "https://sparkquote.ai/mcp",
"enabled": true
}
}
}{
"mcpServers": {
"nec-calculators": {
"type": "http",
"url": "https://sparkquote.ai/mcp"
}
},
"deeplink": "cursor://anysphere.cursor-deeplink/mcp/install?name=nec-calculators&config=eyJ0eXBlIjoiaHR0cCIsInVybCI6Imh0dHBzOi8vc3BhcmtxdW90ZS5haS9tY3AifQ%3D%3D"
}{
"servers": {
"nec-calculators": {
"type": "http",
"url": "https://sparkquote.ai/mcp"
}
}
}{
"mcpServers": {
"nec-calculators": {
"httpUrl": "https://sparkquote.ai/mcp"
}
}
}extensions:
"nec-calculators":
enabled: true
name: "nec-calculators"
type: streamable_http
uri: "https://sparkquote.ai/mcp"
timeout: 300
protocol.modernnewest supported version is 2025-11-25; 2026-07-28 not supported, older versions are deprecated until 2027-07-28protocol.statelessonly applies to 2026-07-28 serversprotocol.transportstreamable HTTPprotocol.list_ttlonly applies to 2026-07-28 serversauth.prm, auth.as_metadata, auth.cimdno remote uses OAuthauth.secret_in_urlno templated URLtools.descriptionsevery tool has a descriptiontools.description_lengthdescriptions are concisetools.schemasevery tool has an object input schematools.annotations10 of 10 tools declare readOnlyHint or destructiveHinttools.directory_hintsevery tool declares readOnlyHint, destructiveHint, idempotentHint and openWorldHinttools.token_costabout 2,875 tokens to load every tooltools.api_dumptools are not a one-to-one API dumpstability.changes, stability.rug_pulltool history recorded for 5 of the 7 days neededdeps.known_vulns, deps.mcp_sdk_version, deps.resolvableno npm or PyPI packagewire_sizechangeddescriptionMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor.
Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.
Full history: list_changes · trend: quality JSON.
Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed. How it is computed.
+dns-namespace +website +reachable +uptime-100% +updated-6d-ago -no-repository
Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed. How it is computed.
| remote | auth | reachable | uptime 30d | p50 | protocol | last ok |
|---|---|---|---|---|---|---|
https://sparkquote.ai/mcp streamable-http | none | yes | 100% | 379 ms | 2025-11-25 | 2026-10-20 |
bid_calculatorread-only | Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)). |
box_fillread-only | Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor. |
conduit_fillread-only | Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5. |
load_calculatorread-only | Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA. |
nec_ampacityread-only | Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits. |
ohms_lawread-only | Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated. |
panel_scheduleread-only | Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance. |
voltage_dropread-only | Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase). |
watts_to_ampsread-only | Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value. |
wire_sizeread-only | Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors. |
Schemas: list_tools.
{
"name": "ai.sparkquote/nec-calculators",
"icons": [
{
"src": "https://sparkquote.ai/logo.png",
"sizes": [
"512x512"
],
"mimeType": "image/png"
},
{
"src": "https://sparkquote.ai/icon.svg",
"sizes": [
"any"
],
"mimeType": "image/svg+xml"
}
],
"title": "SparkQuote NEC calculators",
"$schema": "https://static.modelcontextprotocol.io/schemas/2025-12-11/server.schema.json",
"remotes": [
{
"url": "https://sparkquote.ai/mcp",
"type": "streamable-http"
}
],
"version": "1.0.1",
"websiteUrl": "https://sparkquote.ai/tools/mcp-server",
"description": "NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load."
}