protogrid

Search / ai.sparkquote/nec-calculators

SparkQuote NEC calculators

R0· no sign-in

NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.

v1.0.1 · active · website · descriptor JSON · versions

An agent can connect right now, no human step.Remote endpoint, no authentication, reachable on the last probe.
Quality89new
Trust83of 100
Uptime, 30 days100%
Latency p50379 ms

Connect

8 clients · secrets stay placeholders
{
  "mcpServers": {
    "nec-calculators": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
claude mcp add --transport http nec-calculators https://sparkquote.ai/mcp
[mcp_servers.nec-calculators]
url = "https://sparkquote.ai/mcp"
{
  "$schema": "https://opencode.ai/config.json",
  "mcp": {
    "nec-calculators": {
      "type": "remote",
      "url": "https://sparkquote.ai/mcp",
      "enabled": true
    }
  }
}
{
  "mcpServers": {
    "nec-calculators": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  },
  "deeplink": "cursor://anysphere.cursor-deeplink/mcp/install?name=nec-calculators&config=eyJ0eXBlIjoiaHR0cCIsInVybCI6Imh0dHBzOi8vc3BhcmtxdW90ZS5haS9tY3AifQ%3D%3D"
}
{
  "servers": {
    "nec-calculators": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
{
  "mcpServers": {
    "nec-calculators": {
      "httpUrl": "https://sparkquote.ai/mcp"
    }
  }
}
extensions:
  "nec-calculators":
    enabled: true
    name: "nec-calculators"
    type: streamable_http
    uri: "https://sparkquote.ai/mcp"
    timeout: 300

Quality 89 / 100new

protocol75 · weight 25
  • warn
    protocol.modernnewest supported version is 2025-11-25; 2026-07-28 not supported, older versions are deprecated until 2027-07-28
  • n/a
    protocol.statelessonly applies to 2026-07-28 servers
  • pass
    protocol.transportstreamable HTTP
  • n/a
    protocol.list_ttlonly applies to 2026-07-28 servers
authorizationn/a · weight 15
  • n/a
    auth.prm, auth.as_metadata, auth.cimdno remote uses OAuth
  • n/a
    auth.secret_in_urlno templated URL
tool hygiene100 · weight 30
  • pass
    tools.descriptionsevery tool has a description
  • pass
    tools.description_lengthdescriptions are concise
  • pass
    tools.schemasevery tool has an object input schema
  • pass
    tools.annotations10 of 10 tools declare readOnlyHint or destructiveHint
  • pass
    tools.directory_hintsevery tool declares readOnlyHint, destructiveHint, idempotentHint and openWorldHint
  • pass
    tools.token_costabout 2,875 tokens to load every tool
  • pass
    tools.api_dumptools are not a one-to-one API dump
stabilityn/a · weight 15
  • n/a
    stability.changes, stability.rug_pulltool history recorded for 5 of the 7 days needed
dependenciesn/a · weight 15
  • n/a
    deps.known_vulns, deps.mcp_sdk_version, deps.resolvableno npm or PyPI package

10 tools, about 2,875 tokens to load them all · tool set dcbccfd2a427 · tools last changed 2026-10-15 · checked 2026-10-20 19:10 UTC

Tool changes

  • wire_sizechangeddescription
    before

    Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor.

    after · 79% of words in common

    Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.

Full history: list_changes · trend: quality JSON.

Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed. How it is computed.

Trust 83 / 100

no-repository
provenance55
liveness100
freshness100
hygiene80

+dns-namespace +website +reachable +uptime-100% +updated-6d-ago -no-repository

Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed. How it is computed.

Endpoints

remoteauthreachableuptime 30dp50protocollast ok
https://sparkquote.ai/mcp streamable-httpnoneyes100%379 ms2025-11-252026-10-20

Tools (10)

bid_calculatorread-onlyElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).
box_fillread-onlyMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.
conduit_fillread-onlyPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.
load_calculatorread-onlyDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.
nec_ampacityread-onlyAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.
ohms_lawread-onlyOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.
panel_scheduleread-onlyLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.
voltage_dropread-onlyVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).
watts_to_ampsread-onlyCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.
wire_sizeread-onlyMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.

Schemas: list_tools.

Similar MCP servers

Official server.json
{
  "name": "ai.sparkquote/nec-calculators",
  "icons": [
    {
      "src": "https://sparkquote.ai/logo.png",
      "sizes": [
        "512x512"
      ],
      "mimeType": "image/png"
    },
    {
      "src": "https://sparkquote.ai/icon.svg",
      "sizes": [
        "any"
      ],
      "mimeType": "image/svg+xml"
    }
  ],
  "title": "SparkQuote NEC calculators",
  "$schema": "https://static.modelcontextprotocol.io/schemas/2025-12-11/server.schema.json",
  "remotes": [
    {
      "url": "https://sparkquote.ai/mcp",
      "type": "streamable-http"
    }
  ],
  "version": "1.0.1",
  "websiteUrl": "https://sparkquote.ai/tools/mcp-server",
  "description": "NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load."
}