# Timberr Framing Tools

> Planning calculators for structural framing and building projects.

- name: com.timberrframing/tools
- version: 1.0.0
- connection class: R0 (autonomous)
- trust: 79/100 flags: no-repository
- quality: 86/100 (good)
- owner: not claimed
- descriptor: https://api.protogrid.dev/v1/servers/com.timberrframing%2Ftools
- tools: https://api.protogrid.dev/v1/servers/com.timberrframing%2Ftools/tools

**An agent can connect right now, no human step.** Remote endpoint, no authentication, reachable on the last probe.

## Connection (mcpServers)

```json
{
  "mcpServers": {
    "tools": {
      "type": "http",
      "url": "https://timberrframing.com/mcp"
    }
  }
}
```


## Trust

- hygiene: 80
- liveness: 99
- freshness: 100
- provenance: 45
- drivers: +dns-namespace +reachable +uptime-98% +updated-13d-ago -no-repository
- Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed.

## Quality 86/100 (good)

### protocol: 75 (weight 25)

- warn `protocol.modern`: newest supported version is 2025-11-25; 2026-07-28 not supported, older versions are deprecated until 2027-07-28
- n/a `protocol.stateless`: only applies to 2026-07-28 servers
- pass `protocol.transport`: streamable HTTP
- n/a `protocol.list_ttl`: only applies to 2026-07-28 servers

### authorization: n/a (weight 15)

- n/a `auth.prm`, `auth.as_metadata`, `auth.cimd`: no remote uses OAuth
- n/a `auth.secret_in_url`: no templated URL

### tool hygiene: 89 (weight 30)

- pass `tools.descriptions`: every tool has a description
- pass `tools.description_length`: descriptions are concise
- pass `tools.schemas`: every tool has an object input schema
- pass `tools.annotations`: 15 of 15 tools declare readOnlyHint or destructiveHint
- fail `tools.directory_hints`: no tool declares all four of readOnlyHint, destructiveHint, idempotentHint and openWorldHint; missing: floor_joist_span_calculator (destructiveHint, idempotentHint, openWorldHint); sheathing_sheet_calculator (destructiveHint, idempotentHint, openWorldHint); firewall_and_party_wall_fire_rating_checker (destructiveHint, idempotentHint, openWorldHint); …
- pass `tools.token_cost`: about 5,881 tokens to load every tool
- pass `tools.api_dump`: tools are not a one-to-one API dump
- pass `tools.hidden_text`: no hidden text in tool names, descriptions, schemas or annotations
- pass `tools.poisoning`: no instructions aimed at the model in tool definitions

### stability: 100 (weight 15)

- pass `stability.changes`: 1 tool changes in 30 days
- pass `stability.rug_pull`: no tool changed its meaning under the same name
- pass `stability.new_links`: no tool change named a new site

### dependencies: n/a (weight 15)

- n/a `deps.known_vulns`, `deps.mcp_sdk_version`, `deps.resolvable`: no npm or PyPI package

- tools: 15, about 5,881 tokens to load them all
- tool set hash: 2ac35746ca6e910f28f7468c05449e78
- tools last changed: 2026-11-27T22:31:01.700Z
- badge: [![protogrid quality](https://protogrid.dev/badge/com.timberrframing/tools.svg)](https://protogrid.dev/servers/com.timberrframing/tools)
- Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed.

### Definition changes

- 2026-11-27 `window_and_door_rough_opening_planner` added no new version (still 1.0.0)
  - Rough opening width and height for a list of windows and doors from the unit sizes and the side, top and sill gaps you enter, one printable row per opening. Source: Arithmetic on the unit size and gaps you enter; the manufacturer rough opening table for each unit governs.

Full history: https://api.protogrid.dev/v1/servers/com.timberrframing%2Ftools/changes

## Remotes

- https://timberrframing.com/mcp (streamable-http, auth none, reachable true, uptime30d 0.98)

## Packages

_none_

## Tools (15)

- `deck_joist_and_beam_span_calculator`: Maximum deck joist span from Table 9.23.4.2.-A, the smallest built-up lumber beam from Table 9.23.4.2.-H for your post spacing, and the minimum post size from Article 9.17.4.1. of the 2024 Ontario Building Code. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-A and 9.23.4.2.-H, Articles 9.4.2.3., 9.4.2.2., 9.17.1.1. and 9.17.4.1., and SB-1 Table 2.
- `firewall_and_party_wall_fire_rating_checker`: Fire-resistance rating and sound rating the 2024 Ontario Building Code Part 9 requires for a wall between dwelling units: a party wall on a property line (townhouse, semi-detached), a wall between suites in one building, a house with a secondary suite, or a garage wall. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Articles 9.10.8.1., 9.10.9.15., 9.10.9.16., 9.10.9.18., 9.10.11.1. to 9.10.11.4., 9.11.1.1. and 9.11.1.3., and Article 3.1.10.2. to 3.1.10.5.
- `floor_joist_span_calculator`: Maximum floor joist span for dimension lumber from Table 9.23.4.2.-A of the 2024 Ontario Building Code, and whether your clear span is within it. Source: Ontario Building Code 2024, Division B, Table 9.23.4.2.-A, Maximum Spans for Floor Joists, General Cases.
- `lintel_size_lookup`: Smallest sawn lumber lintel over a door or window opening in a loadbearing wall, from Tables 9.23.12.3.-A to C of the 2024 Ontario Building Code. Source: Ontario Building Code 2024, Division B, Tables 9.23.12.3.-A to 9.23.12.3.-C, Maximum Spans for Lintels (No. 1 or No. 2 grade lumber).
- `load_bearing_wall_removal_beam_sizer_guide`: Checks whether removing a load-bearing wall can stay inside the Ontario Building Code Part 9 beam tables, flags when an engineer is needed, and lists the published beam size ranges from Tables 9.23.4.2.-H to -L and 9.23.4.3.-A to -J. It is not a design. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-H to -L, 9.23.4.3. and 9.23.4.3.-A to -J, Articles 9.4.1.1. and 9.23.4.1., Note A-9.23.4.2.; Building Code Act, 1992, ss. 1(1) and 8(1).
- `lumber_board_foot_calculator`: Board feet, linear feet and piece counts for a list of dimension lumber sizes, lengths and quantities, with a waste allowance. Source: Board foot arithmetic on nominal size: thickness in x width in x length ft / 12; no code table involved.
- `nailing_schedule_lookup`: Minimum nail length and number or spacing of nails for framing connections, from Table 9.23.3.4. of the 2024 Ontario Building Code. Filter by part of the frame and search words. Source: Ontario Building Code 2024, Division B, Table 9.23.3.4., Nailing for Framing.
- `post_and_footing_size_calculator`: Minimum footing area and thickness for a post or column from Table 9.15.3.4. (house) or from the 2.4 kPa deck load over 75 kPa soil, the minimum post size from Article 9.17.4.1., and the minimum foundation depth from Table 9.12.2.2. of the 2024 Ontario Building Code. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Articles 9.15.1.1., 9.15.3.3. to 9.15.3.8., 9.4.2.3., 9.4.4.1. (Table 9.4.4.1.), 9.12.2.2. (Table 9.12.2.2.) and 9.17.1.1. to 9.17.4.1.
- `roof_pitch_rafter_length_calculator`: Common rafter length, roof angle, slope factor and plumb cut from the roof pitch, building span, overhang and ridge board thickness. Source: Roof geometry (Pythagorean slope factor); no code table involved.
- `roof_rafter_span_calculator`: Maximum horizontal span of a wood roof rafter from Table 9.23.4.2.-F of the 2024 Ontario Building Code for specified roof snow loads of 1.0 to 2.0 kPa. Source: Ontario Building Code 2024, Division B, Table 9.23.4.2.-F, Maximum Spans for Roof Rafters, Specified Roof Snow Loads 1.0 to 2.0 kPa.
- `sheathing_sheet_calculator`: Sheets of plywood or OSB needed to cover a floor, wall or sloped roof from its size, roof pitch, openings and waste allowance. Source: Area arithmetic (slope factor for roofs); no code table involved.
- `stair_stringer_calculator`: Riser count and height, treads, total run and stringer length for a straight private stair, checked against Table 9.8.4.1. of the 2024 Ontario Building Code. Source: Ontario Building Code 2024, Division B, Part 9, Table 9.8.4.1. and Articles 9.8.3.3. and 9.8.4.2.
- `truss_vs_rafter_span_checker`: Reads the specified roof snow load for an Ontario city from SB-1 and Article 9.4.2.2., then checks whether a site-built rafter in Tables 9.23.4.2.-F and -G of the 2024 Ontario Building Code can span your roof or whether roof trusses are needed. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-F and 9.23.4.2.-G, Articles 9.4.2.1., 9.4.2.2. and 9.23.14.11.; SB-1 Table 2 (Ss and Sr).
- `wall_framing_calculator`: Studs, plate length and plate boards for a framed wall from its length, height, stud spacing, openings, corners and intersections. Source: Timberr Framing counting rules (field studs, king and jack studs, cripples, corners, intersections, plates); headers are not sized.
- `window_and_door_rough_opening_planner`: Rough opening width and height for a list of windows and doors from the unit sizes and the side, top and sill gaps you enter, one printable row per opening. Source: Arithmetic on the unit size and gaps you enter; the manufacturer rough opening table for each unit governs.
