# EcoCheck

> Vietnam GHG inventory obligation checker, 2026 regulations, CBAM and ESG articles (read-only).

- name: ai.ecocheck/ecocheck
- version: 1.0.0
- connection class: R0 (autonomous)
- trust: 82/100 flags: no-repository
- quality: 95/100 (strong)
- owner: not claimed
- descriptor: https://api.protogrid.dev/v1/servers/ai.ecocheck%2Fecocheck
- tools: https://api.protogrid.dev/v1/servers/ai.ecocheck%2Fecocheck/tools

**An agent can connect right now, no human step.** Remote endpoint, no authentication, reachable on the last probe.

## Connection (mcpServers)

```json
{
  "mcpServers": {
    "ecocheck": {
      "type": "http",
      "url": "https://ecocheck.ai/mcp"
    }
  }
}
```


## Trust

- hygiene: 80
- liveness: 97
- freshness: 100
- provenance: 55
- drivers: +dns-namespace +website +reachable +uptime-92% +updated-14d-ago -no-repository
- Derived from observable signals (official registry feed and our own credential-free probes); no code audit performed.

## Quality 95/100 (strong)

### protocol: 100 (weight 25)

- pass `protocol.modern`: supports 2026-07-28 (server/discover)
- pass `protocol.stateless`: answers without a session
- pass `protocol.transport`: streamable HTTP
- pass `protocol.list_ttl`: tool list is cacheable (ttlMs 3600000)

### authorization: n/a (weight 15)

- n/a `auth.prm`, `auth.as_metadata`, `auth.cimd`: no remote uses OAuth
- n/a `auth.secret_in_url`: no templated URL

### tool hygiene: 100 (weight 30)

- pass `tools.descriptions`: every tool has a description
- pass `tools.description_length`: descriptions are concise
- pass `tools.schemas`: every tool has an object input schema
- pass `tools.annotations`: 14 of 14 tools declare readOnlyHint or destructiveHint
- pass `tools.directory_hints`: every tool declares readOnlyHint, destructiveHint, idempotentHint and openWorldHint
- pass `tools.token_cost`: about 2,946 tokens to load every tool
- pass `tools.api_dump`: tools are not a one-to-one API dump

### stability: 75 (weight 15)

- warn `stability.changes`: 25 tool changes in 30 days
- pass `stability.rug_pull`: no tool changed its meaning under the same name

### dependencies: n/a (weight 15)

- n/a `deps.known_vulns`, `deps.mcp_sdk_version`, `deps.resolvable`: no npm or PyPI package

- tools: 14, about 2,946 tokens to load them all
- tool set hash: 4ab5884ba0a5a85ffa5d172e2feca422
- tools last changed: 2026-10-20T01:20:35.384Z
- badge: [![protogrid quality](https://protogrid.dev/badge/ai.ecocheck/ecocheck.svg)](https://protogrid.dev/servers/ai.ecocheck/ecocheck)
- Checks run on what our credential-free, read-only probes observe; tools are never called and no code audit is performed.

### Tool changes

- 2026-10-20 `get_ghg_regulations` changed (description)
  - before: Key verified facts for Vietnam GHG compliance in 2026: Decision 42/2026 facility list (2,441 facilities), reporting deadline 31/3/2027, pilot ETS allowances (Decision 263), EU CBAM 2027 dates. Each item links to an EcoCheck explainer.
  - after: Key verified facts for Vietnam GHG compliance in 2026: Decision 42/2026 facility list (2,441 facilities), reporting deadline 31/3/2027, pilot ETS allowances (Decision 263) and surrender rules (borrowing ≤15%, offsets ≤30%), domestic carbon exchange (Decree 29/2026), EU CBAM 2027 dates. Each item links to an EcoCheck explainer.
- 2026-10-20 `check_ghg_inventory_obligation` changed (inputSchema)
- 2026-10-19 `ghg_emission_factors` changed (title, description, inputSchema, annotations)
  - before: Built-in default factors used by calculate_ghg_inventory: fuels (NCV, CO2/CH4/N2O, density), refrigerant GWPs (AR5 / AR6), GWP sets. Cite them in the report.
  - after: Built-in default factors used by calculate_ghg_inventory: fuels (NCV, CO2/CH4/N2O, density), refrigerant GWPs (AR5 / AR6), GWP sets, official Viet Nam grid emission factors by year (2024 = 0.6187 tCO2/MWh, CV 1232/BNNMT-BĐKH 30/09/2026). Cite them in the report.
- 2026-10-19 `calculate_ghg_inventory` changed (description, inputSchema)
  - before: GHG inventory from activity data, reported by ISO 14064-1 category (1-6), GHG Protocol scope and gas: fuels (IPCC 2006 tier-1 defaults; litres, kg, t, GJ, MWh…; stationary or mobile), purchased electricity (give the official grid factor of the year — no default built in), refrigerant / SF6 recharges (GWP AR5 or AR6), and custom lines with your own factor (Scope 3 via scope3_category). Biogenic CO2 reported separately; optional uncertainty.
  - after: GHG inventory from activity data, reported by ISO 14064-1 category (1-6), GHG Protocol scope and gas: fuels (IPCC 2006 tier-1 defaults; litres, kg, t, GJ, MWh…; stationary or mobile), purchased electricity (official Viet Nam grid factor of the year built in — 2024 = 0.6187 tCO2/MWh, CV 1232/BNNMT-BĐKH — or give your own), refrigerant / SF6 recharges (GWP AR5 or AR6), and custom lines with your own factor (Scope 3 via scope3_category). Biogenic CO2 reported separately; optional uncertainty.
- 2026-10-11 `calculate_ghg_inventory` changed (inputSchema)
- 2026-10-09 `about_ecocheck` changed (title, description, annotations)
  - before: What EcoCheck is, its services, pricing page, case studies and contact.
  - after: What EcoCheck is (company, product, services) with links to its pricing page, case studies and contact page.
- 2026-10-09 `get_article` changed (title, annotations)
- 2026-10-09 `list_articles` changed (title, annotations)
- 2026-10-09 `list_services` changed (title, annotations)
- 2026-10-09 `get_pricing` changed (title, annotations)

Full history: https://api.protogrid.dev/v1/servers/ai.ecocheck%2Fecocheck/changes

## Remotes

- https://ecocheck.ai/mcp (streamable-http, auth none, reachable true, uptime30d 0.9245283)

## Packages

_none_

## Tools (14)

- `about_ecocheck`: What EcoCheck is (company, product, services) with links to its pricing page, case studies and contact page.
- `calculate_ghg_inventory`: GHG inventory from activity data, reported by ISO 14064-1 category (1-6), GHG Protocol scope and gas: fuels (IPCC 2006 tier-1 defaults; litres, kg, t, GJ, MWh…; stationary or mobile), purchased electricity (official Viet Nam grid factor of the year built in — 2024 = 0.6187 tCO2/MWh, CV 1232/BNNMT-BĐKH — or give your own), refrigerant / SF6 recharges (GWP AR5 or AR6), and custom lines with your own factor (Scope 3 via scope3_category). Biogenic CO2 reported separately; optional uncertainty.
- `cbam_default_value`: EU CBAM default value (tCO2e per tonne) of a CN8 code for a country of production, from Implementing Regulation (EU) 2025/2621 as corrected by 2026/1740, with the mark-up of the import year (10 % 2026, 20 % 2027, 30 % from 2028; fertilisers 1 %). When the exact code has no row, returns candidate codes with full descriptions.
- `cbam_scope_check`: EU CBAM: is a product (CN code) in scope, which aggregated goods category, are indirect emissions counted, and its EU default value for the country of production. Use the 8-digit CN code of the customs declaration (4/6 digits give a partial answer).
- `check_ghg_inventory_obligation`: Check whether a Vietnamese facility must do a mandatory greenhouse-gas (GHG) inventory under Decree 06/2022 (amended by 119/2025) and the 2026 list (Decision 42/2026/QĐ-TTg). Thresholds: 3,000 tCO2e, 1,000 TOE or 65,000 t of waste per year.
- `estimate_cbam_cost`: Indicative CBAM certificate cost for the EU importer: embedded emissions (default value with mark-up, or the producer's actual SEE) minus the free-allocation adjustment (Reg 2025/2620 benchmark × CBAM factor 97.5 % in 2026 × CSCF), times the official certificate price (latest quarterly price unless given). Shows the saving with actual data.
- `get_article`: Get one EcoCheck article as Markdown by numeric id or slug (from list_articles / search_ecocheck).
- `get_ghg_regulations`: Key verified facts for Vietnam GHG compliance in 2026: Decision 42/2026 facility list (2,441 facilities), reporting deadline 31/3/2027, pilot ETS allowances (Decision 263) and surrender rules (borrowing ≤15%, offsets ≤30%), domestic carbon exchange (Decree 29/2026), EU CBAM 2027 dates. Each item links to an EcoCheck explainer.
- `get_pricing`: EcoCheck software plans (Basic free, Pro 4,950,000 VND/month, Pro+ 10,950,000 VND/month, Advanced custom) and where to find inventory-service cost ranges.
- `ghg_emission_factors`: Built-in default factors used by calculate_ghg_inventory: fuels (NCV, CO2/CH4/N2O, density), refrigerant GWPs (AR5 / AR6), GWP sets, official Viet Nam grid emission factors by year (2024 = 0.6187 tCO2/MWh, CV 1232/BNNMT-BĐKH 30/09/2026). Cite them in the report.
- `iso14064_guide`: Practical guidance for an ISO 14064-1 organization inventory (paraphrased, not the standard text): categories and boundaries with the Scope 1/2/3 cross-walk, significance of indirect emissions, quantification, base year and recalculation, uncertainty, report content and review checklist, ISO 14064-3 verification evidence, Vietnam Decree 06 / Decision 42/2026 obligations.
- `list_articles`: List EcoCheck articles (Vietnamese), newest first, optionally filtered by keyword.
- `list_services`: List EcoCheck services: GHG inventory service, inventory software platform, CBAM reporting, ESG reporting, free obligation lookup tool, Academy.
- `search_ecocheck`: Search EcoCheck services, regulations and Vietnamese articles on GHG inventory, Scope 1/2/3, CBAM, carbon credits and ESG. Returns ranked matches with URLs.
